MPC8536DS Freescale Semiconductor, MPC8536DS Datasheet - Page 568

BOARD DEV SYSTEM MPC8536E

MPC8536DS

Manufacturer Part Number
MPC8536DS
Description
BOARD DEV SYSTEM MPC8536E
Manufacturer
Freescale Semiconductor
Series
PowerQUICC III™r
Type
MPUr
Datasheets

Specifications of MPC8536DS

Contents
Board, Software and Documentation
Processor Series
MPC85xx
Core
e500
Data Bus Width
32 bit
Maximum Clock Frequency
667 MHz
Operating Supply Voltage
- 0.3 V to + 1.21 V
Maximum Operating Temperature
+ 105 C
Data Ram Size
32 KB
Interface Type
SPI, USB
Program Memory Type
DDR2, DDR3, SDRAM
Core Size
32 Bit
Program Memory Size
544KB
Cpu Speed
1.5GHz
Digital Ic Case Style
BGA
No. Of Pins
783
Supply Voltage Range
0.95V To 1.05V
Rohs Compliant
Yes
For Use With/related Products
MPC8536
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Security Engine (SEC) 3.0
Table 10-63
10.7.6.7
This status register, as seen in
of these internal signals reflect the state of low-level MDEU functions, such as data padding, key padding,
etc., and are not important to the user, however the user should be aware that reads of this register
especially during processing are likely to return non-zero values for many bits between 0:57. The 4 signals
shown are those which are most likely to be of interest to the user.
The MDEU status register is read only. Writing to this location results in address error being reflected in
the MDEU interrupt status register.
10-138
Offset 0x3_6028
Reset
W
R
0–60
Bits
0
61
62
63
describes MDEU reset control register fields.
MDEU Status Register
Name
SR
MI
RI
MPC8536E PowerQUICC III Integrated Processor Reference Manual, Rev. 1
Table 10-63. MDEU Reset Control Register Field Descriptions
Reserved
Reset Interrupt. Writing this bit active high causes MDEU interrupts signaling done and
error to be reset. It further resets the state of the MDEU interrupt status register.
0 No reset
1 Reset interrupt logic
Module initialization is nearly the same as software reset, except that the MDEU Interrupt
mask register remains unchanged.
0 No reset
1 Reset most of MDEU
Software reset is functionally equivalent to hardware reset (the RESET# pin), but only for
the MDEU. All registers and internal state are returned to their defined reset state.
0 No reset
1 Full MDEU reset
Figure
Figure 10-88. MDEU Status Register
10-88, reflects the state of the MDEU internal signals. The majority
All zeros
Description
57
Freescale Semiconductor
HALT ICCR EI DI RD
58
Access: Read only
59 60 61 62 63

Related parts for MPC8536DS