MC68F375BGMZP33 Freescale Semiconductor, MC68F375BGMZP33 Datasheet - Page 316

no-image

MC68F375BGMZP33

Manufacturer Part Number
MC68F375BGMZP33
Description
IC MPU 32BIT 33MHZ 217-PBGA
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MC68F375BGMZP33

Processor Type
M683xx 32-Bit
Speed
33MHz
Voltage
5V
Mounting Type
Surface Mount
Package / Case
217-PBGA
Processor Series
M683xx
Core
CPU32
Data Bus Width
32 bit
Program Memory Type
Flash
Program Memory Size
256 KB
Data Ram Size
10 KB
Interface Type
SPI, SCI, CAN
Maximum Clock Frequency
16 MHz
Number Of Programmable I/os
48
Number Of Timers
16
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 16 Channel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68F375BGMZP33
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
MC68F375
REFERENCE MANUAL
Both counters are read only (except in test/freeze/halt modes).
The TouCAN responds to any bus state as described in the CAN protocol, transmitting
an error active or error passive flag, delaying its transmission start time (error passive)
and avoiding any influence on the bus when in the bus off state. The following are the
basic rules for TouCAN bus state transitions:
• Increment by 8 (RX error counter also increments by one)
• Decrement by one
• Avoid decrement when equal to zero
• RX error counter reset to a value between 119 and 127 inclusive, when the Tou-
• Following reset, both counters reset to zero
• Detect values for error passive, bus off and error active transitions
• Cascade usage of TX error counter with an additional internal counter to detect
• If the value of the TX error counter or RX error counter increments to a value
• If the TouCAN is in an error passive state, and either the TX error counter or RX
• If the value of the TX error counter increases to a value greater than 255, the
• If the TouCAN is in the bus off state, the TX error counter and an additional inter-
• If only one node is operating in a system, the TX error counter is incremented with
• If the RX error counter increments to a value greater than 127, it stops increment-
CAN transitions from error passive to error active
the 128 occurrences of 11 consecutive recessive bits necessary to transition from
bus off into error active.
greater than or equal to 128, the fault confinement state (FCS[1:0]) field in the
error status register is updated to reflect an error passive state.
error counter decrements to a value less than or equal to 127 while the other error
counter already satisfies this condition, the FCS[1:0] field in the error status reg-
ister is updated to reflect an error active state.
FCS[1:0] field in the error status register is updated to reflect a bus off state, and
an interrupt may be issued. The value of the TX error counter is reset to zero.
nal counter are cascaded to count 128 occurrences of 11 consecutive recessive
bits on the bus. To do this, the TX error counter is first reset to zero, and then the
internal counter begins counting consecutive recessive bits. Each time the inter-
nal counter counts 11 consecutive recessive bits, the TX error counter is incre-
mented by one and the internal counter is reset to zero. When the TX error
counter reaches the value of 128, the FCS[1:0] field in the error status register is
updated to be error active, and both error counters are reset to zero. Any time a
dominant bit is detected following a stream of less than 11 consecutive recessive
bits, the internal counter resets itself to zero but does not affect the TX error
counter value.
each message it attempts to transmit, due to the resulting acknowledgment er-
rors. However, acknowledgment errors never cause the TouCAN to change from
the error passive state to the bus off state.
ing, even if more errors are detected while being a receiver. After the next suc-
cessful message reception, the counter is reset to a value between 119 and 127,
to enable a return to the error active state.