MC68F375BGMZP33 Freescale Semiconductor, MC68F375BGMZP33 Datasheet - Page 192

no-image

MC68F375BGMZP33

Manufacturer Part Number
MC68F375BGMZP33
Description
IC MPU 32BIT 33MHZ 217-PBGA
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MC68F375BGMZP33

Processor Type
M683xx 32-Bit
Speed
33MHz
Voltage
5V
Mounting Type
Surface Mount
Package / Case
217-PBGA
Processor Series
M683xx
Core
CPU32
Data Bus Width
32 bit
Program Memory Type
Flash
Program Memory Size
256 KB
Data Ram Size
10 KB
Interface Type
SPI, SCI, CAN
Maximum Clock Frequency
16 MHz
Number Of Programmable I/os
48
Number Of Timers
16
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 16 Channel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68F375BGMZP33
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
MC68F375
REFERENCE MANUAL
BQ2
00
63
The queue operating mode selected for queue 1 determines what type of trigger event
causes the execution of each of the subqueues within queue 1. Similarly, the queue
operating mode for queue 2 determines the type of trigger event required to execute
each of the subqueues within queue 2.
The choice of single-scan or continuous-scan applies to the full queue, and is not
applied to each subqueue. Once a subqueue is initiated, each CCW is executed
sequentially until the last CCW in the subqueue is executed and the pause state is
entered. Execution can only continue with the next CCW, which is the beginning of the
next subqueue. A subqueue cannot be executed a second time before the overall
queue execution has been completed.
Trigger events which occur during the execution of a subqueue are ignored, except
that the trigger overrun flag is set. When continuous-scan mode is selected, a trigger
event occurring after the completion of the last subqueue (after the queue completion
flag is set), causes execution to continue with the first subqueue, starting with the first
CCW in the queue.
P
1
P
P
CONVERSION COMMAND WORD
0
0
0
0
0
0
1
0
0
0
0
1
0
1
0
1
0
1
0
BEGIN QUEUE 1
END-OF-QUEUE 1
END-OF-QUEUE 2
BEGIN QUEUE 2
(CCW) TABLE
PAUSE
PAUSE
PAUSE
PAUSE
PAUSE
PAUSE
Figure 5-7 QADC64 Queue Operation with Pause
QUEUED ANALOG-TO-DIGITAL CONVERTER MODULE-64
Freescale Semiconductor, Inc.
For More Information On This Product,
CHANNEL SELECT,
SAMPLE, HOLD,
CONVERSION
AND
Go to: www.freescale.com
A/D
Rev. 25 June 03
RESULT WORD TABLE
MOTOROLA
QADC64 CQP
5-16
00
63

Related parts for MC68F375BGMZP33