MC68F375BGMZP33 Freescale Semiconductor, MC68F375BGMZP33 Datasheet - Page 282

no-image

MC68F375BGMZP33

Manufacturer Part Number
MC68F375BGMZP33
Description
IC MPU 32BIT 33MHZ 217-PBGA
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MC68F375BGMZP33

Processor Type
M683xx 32-Bit
Speed
33MHz
Voltage
5V
Mounting Type
Surface Mount
Package / Case
217-PBGA
Processor Series
M683xx
Core
CPU32
Data Bus Width
32 bit
Program Memory Type
Flash
Program Memory Size
256 KB
Data Ram Size
10 KB
Interface Type
SPI, SCI, CAN
Maximum Clock Frequency
16 MHz
Number Of Programmable I/os
48
Number Of Timers
16
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 16 Channel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68F375BGMZP33
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
MC68F375
REFERENCE MANUAL
Bit(s)
15:9
8
7
6
5
4
3
RDRF
Name
TDRE
IDLE
RAF
OR
TC
Transmit data register empty. TDRE is set when the byte in TDRx is transferred to the transmit
serial shifter. If this bit is zero, the transfer is yet to occur and a write to TDRx will overwrite the
previous value. New data is not transmitted if TDRx is written without first clearing TDRE.
0 = Transmit data register still contains data to be sent to the transmit serial shifter.
1 = A new character can now be written to the transmit data register.
For transmit queue operation, this bit should be ignored by software.
Transmit complete. TC is set when the transmitter finishes shifting out all data, queued pream-
bles (mark/idle-line), or queued breaks (logic zero).
0 = SCI transmitter is busy.
1 = SCI transmitter is idle.
For transmit queue operation, TC is cleared when SCxSR is read with TC set, followed by a write
to SCTQ[0:15].
Receive data register full. RDRF is set when the contents of the receive serial shifter are trans-
ferred to register RDRx. If one or more errors are detected in the received word, the appropriate
flag(s) (NF, FE, or PF) are set within the same clock cycle.
0 = Receive data register is empty or contains previously read data.
1 = Receive data register contains new data.
For receiver queue operation, this bit should be ignored by software.
Receiver active flag. RAF indicates whether the receiver is busy. This flag is set when the
receiver detects a possible start bit and is cleared when the chosen type of idle line is detected.
RAF can be used to reduce collisions in systems with multiple masters.
0 = SCI receiver is idle.
1 = SCI receiver is busy.
Idle line detected. IDLE is set when the receiver detects an idle-line condition (reception of a min-
imum of 10 or 11 consecutive ones as specified by ILT in SCCxR1). This bit is not set by the idle-
line condition when RWU in SCCxR1 is set. Once cleared, IDLE is not set again until after RDRF
is set (after the line is active and becomes idle again). If a break is received, RDRF is set, allow-
ing a subsequent idle line to be detected again.
Under certain conditions, the IDLE flag may be set immediately following the negation of RE in
SCCxR1. System designs should ensure this causes no detrimental effects.
0 = SCI receiver did not detect an idle-line condition.
1 = SCI receiver detected an idle-line condition.
For receiver queue operation, IDLE is cleared when SCxSR is read with IDLE set, followed by a
read of SCRQ[0:15].
Overrun error. OR is set when a new byte is ready to be transferred from the receive serial shifter
to register RDRx, and RDRx is already full (RDRF is still set). Data transfer is inhibited until OR
is cleared. Previous data in RDRx remains valid, but additional data received during an overrun
condition (including the byte that set OR) is lost.
Note that whereas the other receiver status flags (NF, FE, and PF) reflect the status of data
already transferred to RDRx, the OR flag reflects an operational condition that resulted in a loss
of data to RDRx.
0 = RDRF is cleared before new data arrives.
1 = RDRF is not cleared before new data arrives.
Reserved
Freescale Semiconductor, Inc.
QUEUED SERIAL MULTI-CHANNEL MODULE
For More Information On This Product,
Table 6-25 SCxSR Bit Settings
Go to: www.freescale.com
Rev. 25 June 03
Description
MOTOROLA
6-48