MPC8544VTALF Freescale Semiconductor, MPC8544VTALF Datasheet - Page 564

MPU POWERQUICC III 783-PBGA

MPC8544VTALF

Manufacturer Part Number
MPC8544VTALF
Description
MPU POWERQUICC III 783-PBGA
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MPC8544VTALF

Processor Type
MPC85xx PowerQUICC III 32-Bit
Speed
667MHz
Voltage
1V
Mounting Type
Surface Mount
Package / Case
783-FCPBGA
Processor Series
MPC85xx
Core
e500
Data Bus Width
32 bit
Maximum Clock Frequency
667 MHz
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Data Ram Size
32 KB
I/o Voltage
1.8 V, 3.3 V
Interface Type
I2C, HSSI, DUART
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC8544VTALF
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MPC8544VTALFA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Security Engine (SEC) 2.1
12.4.7.6
The KEU interrupt status register tracks the state of possible errors, provided those errors are not masked,
via the KEU interrupt control register. The definition of each bit in the KEU interrupt status register is
shown in
Table 12-47
12-84
59-60
Address KEU 0x3_E030
0–48
Bits
Bits
61
62
63
49
50
Reset
W
R
Signal
Name
ICCR Integrity check comparison result.
0
ICE
RD
ID
IE
Figure
describes the KEU interrupt status register signals.
KEU Interrupt Status Register (KEUISR)
MPC8544E PowerQUICC III Integrated Host Processor Family Reference Manual, Rev. 1
00 No integrity check comparison was performed.
01 The integrity check comparison passed.
10 The integrity check comparison failed.
11 Reserved
Note: A passed or failed result is generated only if ICV checking is enabled and the algorithm selected is F9.
Interrupt error. Reflects the state of the ERROR interrupt signal, as sampled by the controller interrupt status
register
0 KEU is not signaling error
1 KEU is signaling error
Interrupt done. Reflects the state of the DONE interrupt signal, as sampled by the controller interrupt status
register
0 Processing not done
1 All bytes processed
Reset done. Indicates when the KEU has completed its reset sequence, as reflected in the signal sampled by
the appropriate channel.
0 Reset in progress
1 Reset done
Reserved
Integrity check error.
0 No error detected
1 Integrity check error detected. An ICV check was performed on an F9 result and the supplied ICV did not
Reserved
12-62.
match the one computed by the KEU.
Table 12-46. KEU Status Register Field Descriptions (continued)
(Section 12.6.5.3, “Interrupt Status Register
(Section 12.6.5.3, “Interrupt Status Register
Table 12-47. KEU Interrupt Status Register Field Descriptions
48
Figure 12-62. KEU Interrupt Status Register
ICE
49
50
IE
51
ERE CE KSE DSE DE
52
All zeros
53
Description
Description
(ISR)”).
(ISR)”).
54
55
56
AE OFE IFE
57
58
59
Freescale Semiconductor
60
Access: Read-write
IFO OFU —
61
62
63

Related parts for MPC8544VTALF