R5S72011 RENESAS [Renesas Technology Corp], R5S72011 Datasheet - Page 607

no-image

R5S72011

Manufacturer Part Number
R5S72011
Description
32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7200 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet
(13) Operation when Error Occurs during PWM Mode 2 Operation, and Operation is
Figure 12.137 shows an explanatory diagram of the case where an error occurs in PWM mode 2
and operation is restarted in normal mode after re-setting.
1. After a reset, MTU2 output is low and ports are in the high-impedance state.
2. Set PWM mode 2.
3.
4. Set MTU2 output with the PFC.
5. The count operation is started by TSTR.
6. Output goes low on compare-match occurrence.
7. An error occurs.
8. Set port output with the PFC and output the inverse of the active level.
9. The count operation is stopped by TSTR.
10. Set normal mode.
11. Initialize the pins with TIOR.
12. Set MTU2 output with the PFC.
13. Operation is restarted by TSTR.
compare-match occurrence. In PWM mode 2, the cycle register pins are not initialized. In the
example, TIOC *A is the cycle register.)
MTU2
module output
TIOC*A
TIOC*B
Port output
PB, PC, PD*
PB, PC, PD*
Initialize the pins with TIOR. (The example shows initial high output, with low output on
Restarted in Normal Mode
Notes: 1. This pin is multiplexed with TIOC*A.
Figure 12.137 Error Occurrence in PWM Mode 2, Recovery in Normal Mode
2. This pin is multiplexed with TIOC*B.
1
2
Power-on
reset
1
(PWM2)
TMDR
2
High-Z
High-Z
0 out)
TIOR
(1 init
3
Not initialized (cycle register)
(MTU2)
PFC
4
TSTR
(1)
5
Match
6
occurs
Section 12 Multi-Function Timer Pulse Unit 2 (MTU2)
Error
7
(PORT)
PFC
8
Rev. 2.00 Sep. 07, 2007 Page 579 of 1164
TSTR
(0)
9
(normal)
TMDR
10
(1 init
0 out)
TIOR
11
(MTU2)
PFC
12
REJ09B0321-0200
TSTR
(1)
13

Related parts for R5S72011