Notes: 1. TADCR must not be accessed in eight bits; it should always be accessed in 16 bits.
Bit
4
3
2
1
0
2. When interrupt skipping is disabled (the T3AEN and T4VEN bits in the timer interrupt
3. If link with interrupt skipping is enabled while interrupt skipping is disabled, A/D
*
Bit Name
DT4BE
ITA3AE
ITA4VE
ITB3AE
ITB4VE
skipping set register (TITCR) are cleared to 0 or the skipping count set bits (3ACOR
and 4VCOR) in TITCR are cleared to 0), do not link A/D converter start requests with
interrupt skipping operation (clear the ITA3AE, ITA4VE, ITB3AE, and ITB4VE bits in the
timer A/D converter start request control register (TADCR) to 0).
converter start requests will not be issued.
Do not set to 1 when complementary PWM mode is not selected.
Initial
Value
0*
0*
0*
0*
0*
R/W
R/W
R/W
R/W
R/W
R/W
Description
Down-Count TRG4BN Enable
Enables or disables A/D converter start requests
(TRG4BN) during TCNT_4 down-count operation.
0: A/D converter start requests (TRG4BN) disabled
1: A/D converter start requests (TRG4BN) enabled
TGIA_3 Interrupt Skipping Link Enable
Select whether to link A/D converter start requests
(TRG4AN) with TGIA_3 interrupt skipping operation.
0: Does not link with TGIA_3 interrupt skipping
1: Links with TGIA_3 interrupt skipping
TCIV_4 Interrupt Skipping Link Enable
Select whether to link A/D converter start requests
(TRG4AN) with TCIV_4 interrupt skipping operation.
0: Does not link with TCIV_4 interrupt skipping
1: Links with TCIV_4 interrupt skipping
TGIA_3 Interrupt Skipping Link Enable
Select whether to link A/D converter start requests
(TRG4BN) with TGIA_3 interrupt skipping operation.
0: Does not link with TGIA_3 interrupt skipping
1: Links with TGIA_3 interrupt skipping
TCIV_4 Interrupt Skipping Link Enable
Select whether to link A/D converter start requests
(TRG4BN) with TCIV_4 interrupt skipping operation.
0: Does not link with TCIV_4 interrupt skipping
1: Links with TCIV_4 interrupt skipping
during TCNT_4 down-count operation
during TCNT_4 down-count operation
Section 12 Multi-Function Timer Pulse Unit 2 (MTU2)