MCIMX286CVM4B Freescale Semiconductor, MCIMX286CVM4B Datasheet - Page 937

no-image

MCIMX286CVM4B

Manufacturer Part Number
MCIMX286CVM4B
Description
IC MPU I.MX286 289MAPBGA
Manufacturer
Freescale Semiconductor
Series
i.MX28r

Specifications of MCIMX286CVM4B

Core Processor
ARM9
Core Size
32-Bit
Speed
454MHz
Connectivity
CAN, EBI/EMI, Ethernet, I²C, MMC, SmartCard, SPI, SSI, UART/USART, USB OTG
Peripherals
DMA, I²S, LCD, POR, PWM, WDT
Program Memory Size
128KB (32K x 32)
Program Memory Type
Mask ROM
Ram Size
32K x 32
Voltage - Supply (vcc/vdd)
1.25 V ~ 5.25 V
Data Converters
A/D 17x12b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
289-LFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of I /o
-
Eeprom Size
-
Lead Free Status / Rohs Status
Compliant
11.12.15 Battery Level Monitor Register (HW_POWER_BATTMONITOR)
This register provides brownout controls and monitors the battery voltage.
Address:
Freescale Semiconductor, Inc.
Reset
Reset
BRWNOUT_PWD
BATTBRNOUT_
BATTBRNOUT
5VDETECT_
EN_BATADJ
BATT_VAL
Bit
Bit
W
W
RSRVD3
RSRVD2
ENABLE
R
R
PWDN_
PWDN_
31 26
25 16
15 12
Field
11
10
9
8
31
15
0
0
HW_POWER_BATTMONITOR
40E0h
30
14
RSRVD2
0
0
Reserved.
Software should be configured to place the battery voltage in this register measured with an 8-mV LSB
resolution through the LRADC.This value is used by the DC-DC converter and must be correct before setting
EN_BATADJ.
Reserved.
Enable the use of the programmed 5V detect signal to gate off the powering down of the device when a
battery brownout occurs. Clear this bit to power-down the device when a battery brown-out occurs regardless
of the state of the 5
V detect signal.
This bit enables the DC-DC to improve efficiency and minimize ripple using the information from the
BATT_VAL field. It is very important that BATT_VAL contain accurate information before setting EN_BATADJ.
Note: HW_LRADC_CONVERSION_SCALE_FACTOR must be programmed to 0x2 before setting this bit
to 0x1.
Powers down the device after the DC-DC converter completeS startup if a battery brownout occurs. This
function is only active when 5V is not present. Additionally, software should clear this bit and disable this
function after the system is configured for a battery brownout and the battery brownout interrupt is enabled.
Power-down circuitry for battery brownout detection. This bit should only be set when it is not important to
montior battery brownouts and minimum system power consumption is required.
29
13
RSRVD3
0
0
i.MX28 Applications Processor Reference Manual, Rev. 1, 2010
HW_POWER_BATTMONITOR field descriptions
28
12
0
0
27
11
0
1
26
10
0
0
8004_4000h base + E0h offset = 8004_
25
0
1
9
24
0
0
8
Description
23
0
0
7
RSRVD1
22
0
0
6
BATT_VAL
21
0
5
0
20
0
4
0
Chapter 11 Power Supply
19
BRWNOUT_LVL
0
0
3
18
0
0
2
17
0
0
1
16
0
0
0
937