MPC8308VMAGD Freescale Semiconductor, MPC8308VMAGD Datasheet - Page 507

MPU POWERQUICC II PRO 473MAPBGA

MPC8308VMAGD

Manufacturer Part Number
MPC8308VMAGD
Description
MPU POWERQUICC II PRO 473MAPBGA
Manufacturer
Freescale Semiconductor

Specifications of MPC8308VMAGD

Processor Type
MPC83xx PowerQUICC II Pro 32-Bit
Speed
400MHz
Voltage
1V
Mounting Type
Surface Mount
Package / Case
473-MAPBGA
Product
Network Processor
Data Rate
256 bps
Frequency
400 MHz
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Supply Current (max)
5 uA
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
0 C
Interface
I2C, JTAG, SPI
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC8308VMAGD
Manufacturer:
FREESCAL
Quantity:
300
Part Number:
MPC8308VMAGD
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MPC8308VMAGD
Manufacturer:
FREESCALE
Quantity:
6
Part Number:
MPC8308VMAGD
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
MPC8308VMAGD
Quantity:
2 000
Part Number:
MPC8308VMAGD400/266
Manufacturer:
FREESCAL
Quantity:
300
Part Number:
MPC8308VMAGDA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Company:
Part Number:
MPC8308VMAGDA
Quantity:
4 200
Table 11-16
set, the data transfer can be considered complete.
The relation between command CRC error and command timeout error is shown in
11.4.11 Interrupt Status Enable Register (IRQSTATEN)
Figure 11-13
corresponding interrupt status bit to be set by the specified event. If any bit is cleared, the corresponding
IRQSTAT bit is also cleared and is never set.
Freescale Semiconductor
Table 11-15. Relation Between Command Timeout Error and Command Complete Status
Table 11-17. Relation Between Command CRC Error and Command Timeout Error
below shows that transfer complete has higher priority than data timeout error. If both bits are
Command CRC Error
Table 11-16. Relation Between Data Timeout Error and Transfer Complete Status
shows the interrupt status enable register. Setting the bits of IRQSTATEN enables the
Transfer Complete
Command Complete
Don’t Care
0
0
1
1
0
0
1
MPC8308 PowerQUICC II Pro Processor Reference Manual, Rev. 0
0
1
Command Timeout Error
Command Timeout Error
Data Timeout Error
0
1
0
1
0
0
1
0
1
X
Response not received within 64
Timeout occur during transfer
Meaning of the Status
Response Timeout Error
Meaning of the Status
Response received
Meaning of the Status
Data transfer complete
Response CRC Error
SD_CMD line conflict
SD_CLK cycles
Enhanced Secure Digital Host Controller
No error
Table 11-17
below.
11-27

Related parts for MPC8308VMAGD