R0K572030S000BE Renesas Electronics America, R0K572030S000BE Datasheet - Page 1021

KIT DEV FOR SH7203

R0K572030S000BE

Manufacturer Part Number
R0K572030S000BE
Description
KIT DEV FOR SH7203
Manufacturer
Renesas Electronics America
Series
Renesas Starter Kits (RSK)r
Type
MCUr
Datasheets

Specifications of R0K572030S000BE

Contents
CPU Board, LCD Module, E10A-Lite Emulator, Cable, QuickStart Guide and CD-ROM
Silicon Manufacturer
Renesas
Kit Contents
Board
Silicon Family Name
SH7203
Silicon Core Number
R5S72030W200FP
Tool / Board Applications
General Purpose MCU, MPU, DSP, DSC
Mcu Supported Families
SH7203
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
SH7203
Lead Free Status / Rohs Status
Compliant
Normal Mode:
Listen-Only Mode:
Self Test Mode 1:
Self Test Mode 2:
Write Error Counter: TEC/REC can be written in this mode. RCAN-TL1 can be forced to
Error Passive Mode:
When message error occurs, IRR13 is set in all test modes.
RCAN-TL1 operates in the normal mode.
ISO-11898 requires this mode for baud rate detection. The Error Counters
are cleared and disabled so that the TEC/REC does not increase the values,
and the CTxn (n = 0, 1) Output is disabled so that RCAN-TL1 does not
generate error frames or acknowledgment bits. IRR13 is set when a
message error occurs.
RCAN-TL1 generates its own Acknowledge bit, and can store its own
messages into a reception mailbox (if required). The CRxn/CTxn (n = 0, 1)
pins must be connected to the CAN bus.
RCAN-TL1 generates its own Acknowledge bit, and can store its own
messages into a reception mailbox (if required). The CRxn/CTxn (n = 0, 1)
pins do not need to be connected to the CAN bus or any external devices,
as the internal CTxn (n = 0, 1) is looped back to the internal CRxn (n = 0,
1). CTxn (n = 0, 1) pin outputs only recessive bits and CRxn (n = 0, 1) pin
is disabled.
RCAN-TL1 can be forced to enter Error Passive mode.
become an Error Passive mode by writing a value greater than 127 into the
Error Counters. The value written into TEC is used to write into REC, so
only the same value can be set to these registers. Similarly, RCAN-TL1
can be forced to become an Error Warning by writing a value greater than
95 into them.
RCAN-TL1 needs to be in Halt Mode when writing into TEC/REC
(MCR1 must be "1" when writing to the Error Counter). Furthermore this
test mode needs to be exited prior to leaving Halt mode.
Note: The REC will not be modified by implementing this Mode.
However, once running in Error Passive Mode, the REC will increase
normally should errors be received. In this Mode, RCAN-TL1 will enter
BusOff if TEC reaches 256 (Dec). However when this mode is used
RCAN-TL1 will not be able to become Error Active. Consequently, at the
end of the Bus Off recovery sequence, RCAN-TL1 will move to Error
Passive and not to Error Active.
Section 19 Controller Area Network (RCAN-TL1)
Rev. 3.00 Sep. 28, 2009 Page 989 of 1650
REJ09B0313-0300

Related parts for R0K572030S000BE