MPC555CME Freescale Semiconductor, MPC555CME Datasheet - Page 430

KIT EVALUATION FOR MPC555

MPC555CME

Manufacturer Part Number
MPC555CME
Description
KIT EVALUATION FOR MPC555
Manufacturer
Freescale Semiconductor
Type
Microcontrollerr
Datasheet

Specifications of MPC555CME

Contents
Module Board, Installation Guide, Power Supply, Cable, Software and more
Processor To Be Evaluated
MPC555
Data Bus Width
32 bit
Interface Type
RS-232
For Use With/related Products
MPC555
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
13.10.3 Scan Modes
13.10.3.1 Disabled Mode
13.10.3.2 Reserved Mode
13.10.3.3 Single-Scan Modes
MPC555
USER’S MANUAL
Another pause and end-of-queue boundary condition occurs when the pause and an
end-of-queue condition occur in the same CCW. Both the pause and end-of-queue
conditions are recognized simultaneously. The end-of-queue condition has prece-
dence so a conversion is not performed for the CCW and the pause flag is not set. The
QADC64 sets the completion flag and the queue status becomes idle. Examples of
this situation are:
The QADC64 queuing mechanism provides several methods for automatically scan-
ning input channels. In single-scan mode, a single pass through a sequence of con-
versions defined by a queue is performed. In continuous-scan mode, multiple passes
through a sequence of conversions defined by a queue are executed. The possible
modes are:
The following paragraphs describe the disabled/reserved, single-scan, and continu-
ous-scan operations.
When the disabled mode is selected, the queue is not active. Trigger events cannot
initiate queue execution. When both queue 1 and queue 2 are disabled, wait states are
not encountered for IMB accesses of the RAM. When both queues are disabled, it is
safe to change the QCLK prescaler values.
Reserved mode allows for future mode definitions. When the reserved mode is select-
ed, the queue is not active.
When the application software wants to execute a single pass through a sequence of
conversions defined by a queue, a single-scan queue operating mode is selected. By
programming the MQ field in QACR1 or QACR2, the following modes can be selected:
• The pause bit is set in CCW0 and EOQ is programmed into CCW0
• During queue 1 operation, the pause bit is set in CCW20, which is also BQ2
• Disabled and reserved mode
• Software initiated single-scan mode
• External trigger single-scan mode
• External gated single-scan mode (queue 1 only)
• Interval timer single-scan mode
• Software initiated continuous-scan mode
• External trigger continuous-scan mode
• External gated continuous-scan mode (queue 1 only)
• Interval timer continuous-scan mode
/
MPC556 QUEUED ANALOG-TO-DIGITAL CONVERTER MODULE-64
Do not use a reserved mode. Unspecified operations may result.