MPC555CME Freescale Semiconductor, MPC555CME Datasheet - Page 163

KIT EVALUATION FOR MPC555

MPC555CME

Manufacturer Part Number
MPC555CME
Description
KIT EVALUATION FOR MPC555
Manufacturer
Freescale Semiconductor
Type
Microcontrollerr
Datasheet

Specifications of MPC555CME

Contents
Module Board, Installation Guide, Power Supply, Cable, Software and more
Processor To Be Evaluated
MPC555
Data Bus Width
32 bit
Interface Type
RS-232
For Use With/related Products
MPC555
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3.13.10.1 Fixed-Point Load With Update and Store With Update Instructions
3.13.10.2 Fixed-Point Load and Store Multiple Instructions
3.13.10.3 Fixed-Point Load String Instructions
3.13.10.4 Storage Synchronization Instructions
3.13.10.5 Floating-Point Load and Store With Update Instructions
3.13.10.6 Floating-Point Load Single Instructions
3.13.10.7 Floating-Point Store Single Instructions
MPC555
USER’S MANUAL
For load with update and store with update instructions, where RA = 0, the EA is writ-
ten into R0. For load with update instructions, where RA = RT, RA is boundedly unde-
fined.
For these types of instructions, EA must be a multiple of four. If it is not, the system
alignment error handler is invoked. For a lmw instruction (if RA is in the range of reg-
isters to be loaded), the instruction completes normally. RA is then loaded from the
memory location as follows:
Load string instructions behave the same as load multiple instructions, with respect to
invalid format in which RA is in the range of registers to be loaded. In case RA is in the
range, it is updated from memory.
For these type of instructions, EA must be a multiple of four. If it is not, the system
alignment error handler is invoked.
For Load and Store with update instructions, if RT = 0 then the EA is written into R0.
In case the operand falls in the range of a single denormalized number the floating-
point assist interrupt handler is invoked.
Refer to RCPU Reference Manual (Floating-Point Assist for Denormalized Operands)
for complete description of handling denormalized floating-point numbers.
In case the operand falls in the range of a single denormalized number, the floating-
point assist interrupt handler is invoked.
In case the operand is ZERO it is converted to the correct signed ZERO in single-pre-
cision format.
In case the operand is between the range of single denormalized and double denor-
malized it is considered a programming error. The hardware will handle this case as if
the operand was single denormalized.
In case the operand falls in the range of double denormalized numbers it is considered
a programming error. The hardware will handle this case as if the operand was ZERO.
/
RA ← MEM(EA+(RA-RT)*4, 4)
MPC556
CENTRAL PROCESSING UNIT
Rev. 15 October 2000
MOTOROLA
3-41

Related parts for MPC555CME