MPC561MZP56 Freescale, MPC561MZP56 Datasheet - Page 1015

MPC561MZP56

Manufacturer Part Number
MPC561MZP56
Description
Manufacturer
Freescale
Datasheet

Specifications of MPC561MZP56

Cpu Family
MPC56x
Device Core
PowerPC
Device Core Size
32b
Frequency (max)
56MHz
Interface Type
QSPI/SCI/SPI/UART
Total Internal Ram Size
32KB
# I/os (max)
56
Number Of Timers - General Purpose
22
Operating Supply Voltage (typ)
2.6/5V
Operating Supply Voltage (max)
2.7/5.25V
Operating Supply Voltage (min)
2.5/4.75V
On-chip Adc
2(32-chx10-bit)
Instruction Set Architecture
RISC
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
388
Package Type
BGA
Program Memory Type
ROMLess
Program Memory Size
Not Required
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC561MZP56
Manufacturer:
FREESCALE
Quantity:
852
Part Number:
MPC561MZP56
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MPC561MZP56
Manufacturer:
FREESCALE
Quantity:
852
Company:
Part Number:
MPC561MZP56
Quantity:
13
Part Number:
MPC561MZP56R2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
24.8.3
A trace overrun error occurs when a trace message cannot be queued due to the queue being full, provided
program trace is enabled.
The overrun error causes the message queue to be flushed, and an error message to be queued. The error
code within the error message indicates that either a program/data/ownership trace overrun error has
occurred or that only a program trace overrun has occurred. The next BTM will be a synchronization
message. Refer to
The error message has the following format:
24.8.4
24.8.4.1
BTM is accomplished by capturing instruction fetch information from the U-bus and instruction execution
information from the RCPU (VF and VFLS signals), and combining them to generate program trace
messages.
Freescale Semiconductor
Queue Overflow Program Trace Error Message
Branch Trace Message Operation
BTM Capture and Encoding Algorithm
Table
A1
Previous Address (A1) = 0x0003 FC01, New Address (A2) = 0x0003 F365
Address Message (M1) = 1111 0110 0100
Figure 24-33. Relative Address Generation and Re-Creation
+
24-20.
Figure 24-34. Error Message (Queue Overflow) Format
M1 = A2
+
M1 = 0000 0000 0000 0000 0000 1111 0110 0100
A1 = 0000 0000 0000 0011 1111 1100 0000 0001
A2 = 0000 0000 0000 0011 1111 0011 0110 0101
+
MPC561/MPC563 Reference Manual, Rev. 1.2
M1 = 0000 0000 0000 0000 0000 1111 0110 0100
TCODE (8)
A2 = 0000 0000 0000 0011 1111 0011 0110 0101
A1 = 0000 0000 0000 0011 1111 1100 0000 0000
[6 bits]
Message Generation:
Address Re-Creation:
Length = 11 bits
Error Code (0b0 0000,
0b0 0001, 0b0 0010,
0b0 0111)
[5 bits]
READI Module
24-47