MPC561MZP56 Freescale, MPC561MZP56 Datasheet - Page 1008

MPC561MZP56

Manufacturer Part Number
MPC561MZP56
Description
Manufacturer
Freescale
Datasheet

Specifications of MPC561MZP56

Cpu Family
MPC56x
Device Core
PowerPC
Device Core Size
32b
Frequency (max)
56MHz
Interface Type
QSPI/SCI/SPI/UART
Total Internal Ram Size
32KB
# I/os (max)
56
Number Of Timers - General Purpose
22
Operating Supply Voltage (typ)
2.6/5V
Operating Supply Voltage (max)
2.7/5.25V
Operating Supply Voltage (min)
2.5/4.75V
On-chip Adc
2(32-chx10-bit)
Instruction Set Architecture
RISC
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
388
Package Type
BGA
Program Memory Type
ROMLess
Program Memory Size
Not Required
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC561MZP56
Manufacturer:
FREESCALE
Quantity:
852
Part Number:
MPC561MZP56
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MPC561MZP56
Manufacturer:
FREESCALE
Quantity:
852
Company:
Part Number:
MPC561MZP56
Quantity:
13
Part Number:
MPC561MZP56R2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
READI Module
24.8.2.3
In case of a mispredicted branch or an exception, a program trace correction message may also be sent
indicating a number which corrects the number of instructions (not messages) in the trace.
In the case of a synchronizing branch trace message getting corrected due to a misprediction or an
exception, the next branch trace message will be a synchronizing message.
Table 24-27
Table 24-28
24-40
illustrates an example of a program trace correction message in case of a mispredicted branch.
illustrates an example of a program trace correction message in case of an exception.
Correction Messages
Time
In case of a mispredicted branch, the correction count is always 1 and the
sequential instruction count is reset to 1 (to denote the not-taken branch as
a sequential instruction), after the program trace correction message is sent.
This is because a mispredicted branch is considered to be a sequential
instruction.
In case of an exception, the sequential instruction count is reset to 0, after
the program trace correction message is sent.
10
11
12
13
1
2
3
4
5
6
7
8
9
Table 24-27. Program Trace Correction Due to a Mispredicted Branch
Indirect Branch Instruction
Direct Branch Instruction
Sequential Instruction
Sequential Instruction
Sequential Instruction
Sequential Instruction
Sequential Instruction
Sequential Instruction
Sequential Instruction
Sequential Instruction
Sequential Instruction
Sequential Instruction
Sequential Instruction
(mispredicted taken)
Processor State
MPC561/MPC563 Reference Manual, Rev. 1.2
NOTE
NOTE
Direct Branch Message
TCODE = 3
Number of sequential instructions executed
since last taken branch = 5
Indirect Branch Message
TCODE = 4
Number of sequential instructions executed
since last taken branch = 4
Unique portion of the target address
Message sent
Freescale Semiconductor