HD64F3026X25 Renesas Electronics America, HD64F3026X25 Datasheet - Page 491

MCU 3V 256K 100-TQFP

HD64F3026X25

Manufacturer Part Number
HD64F3026X25
Description
MCU 3V 256K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD64F3026X25

Core Processor
H8/300H
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
PWM, WDT
Number Of I /o
70
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3026X25
Manufacturer:
Renesas Electronics America
Quantity:
10 000
14.4
The A/D converter operates by successive approximations with 10-bit resolution. It has two
operating modes: single mode and scan mode.
14.4.1
Single mode should be selected when only one A/D conversion on one channel is required. A/D
conversion starts when the ADST bit is set to 1 by software, or by external trigger input. The
ADST bit remains set to 1 during A/D conversion and is automatically cleared to 0 when
conversion ends.
When conversion ends the ADF flag is set to 1. If the ADIE bit is also set to 1, an ADI interrupt is
requested at this time. To clear the ADF flag to 0, first read ADCSR, then write 0 in ADF.
When the mode or analog input channel must be switched during analog conversion, to prevent
incorrect operation, first clear the ADST bit to 0 in ADCSR to halt A/D conversion. After making
the necessary changes, set the ADST bit to 1 to start A/D conversion again. The ADST bit can be
set at the same time as the mode or channel is changed.
Typical operations when channel 1 (AN
Figure 14.3 shows a timing diagram for this example.
1. Single mode is selected (SCAN = 0), input channel AN
2. When A/D conversion is completed, the result is transferred into ADDRB. At the same time
3. Since ADF = 1 and ADIE = 1, an ADI interrupt is requested.
4. The A/D interrupt handling routine starts.
5. The routine reads ADCSR, then writes 0 in the ADF flag.
6. The routine reads and processes the conversion result (ADDRB).
7. Execution of the A/D interrupt handling routine ends. After that, if the ADST bit is set to 1,
CH0 = 1), the A/D interrupt is enabled (ADIE = 1), and A/D conversion is started
(ADST = 1).
the ADF flag is set to 1, the ADST bit is cleared to 0, and the A/D converter becomes idle.
A/D conversion starts again and steps 2 to 7 are repeated.
Single Mode (SCAN = 0)
Operation
1
) is selected in single mode are described next.
Rev. 2.00 Sep 20, 2005 page 451 of 800
1
is selected (CH2 = CH1 = 0,
Section 14 A/D Converter
REJ09B0260-0200

Related parts for HD64F3026X25