MK30DN512ZVLK10 Freescale Semiconductor, MK30DN512ZVLK10 Datasheet - Page 823

no-image

MK30DN512ZVLK10

Manufacturer Part Number
MK30DN512ZVLK10
Description
ARM Microcontrollers - MCU KINETIS 512K SLCD
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MK30DN512ZVLK10

Core
ARM Cortex M4
Processor Series
K30
Data Bus Width
32 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
512 KB
Data Ram Size
128 KB
On-chip Adc
Yes
Operating Supply Voltage
1.71 V to 3.6 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-80
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MK30DN512ZVLK10
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Reset
36.3.17 Channels Polarity (FTMx_POL)
This register defines the output polarity of the FTM channels.
Addresses: FTM0_POL is 4003_8000h base + 70h offset = 4003_8070h
Freescale Semiconductor, Inc.
Bit
W
R
CH4TRIG
CH3TRIG
CH2TRIG
31
0
Field
30
2
1
0
0
FTM1_POL is 4003_9000h base + 70h offset = 4003_9070h
FTM2_POL is 400B_8000h base + 70h offset = 400B_8070h
29
0
28
0
The safe value that is driven in a channel output when the fault
control is enabled and a fault condition is detected is the
inactive state of the channel. That is, the safe value of a channel
is the value of its POL bit.
Enable the generation of the channel trigger when the FTM counter is equal to the CnV register.
0
1
Channel 4 Trigger Enable
Enable the generation of the channel trigger when the FTM counter is equal to the CnV register.
0
1
Channel 3 Trigger Enable
Enable the generation of the channel trigger when the FTM counter is equal to the CnV register.
0
1
Channel 2 Trigger Enable
Enable the generation of the channel trigger when the FTM counter is equal to the CnV register.
0
1
27
0
The generation of the channel trigger is disabled.
The generation of the channel trigger is enabled.
The generation of the channel trigger is disabled.
The generation of the channel trigger is enabled.
The generation of the channel trigger is disabled.
The generation of the channel trigger is enabled.
The generation of the channel trigger is disabled.
The generation of the channel trigger is enabled.
26
0
25
0
FTMx_EXTTRIG field descriptions (continued)
24
0
K30 Sub-Family Reference Manual, Rev. 6, Nov 2011
23
0
22
0
21
0
Reserved
20
0
19
0
18
0
NOTE
17
0
16
0
15
0
Description
14
0
13
0
12
0
11
0
10
0
0
9
0
8
Chapter 36 FlexTimer (FTM)
0
7
0
6
0
5
4
0
0
3
0
2
0
1
823
0
0