MK30DN512ZVLK10 Freescale Semiconductor, MK30DN512ZVLK10 Datasheet - Page 1045

no-image

MK30DN512ZVLK10

Manufacturer Part Number
MK30DN512ZVLK10
Description
ARM Microcontrollers - MCU KINETIS 512K SLCD
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MK30DN512ZVLK10

Core
ARM Cortex M4
Processor Series
K30
Data Bus Width
32 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
512 KB
Data Ram Size
128 KB
On-chip Adc
Yes
Operating Supply Voltage
1.71 V to 3.6 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-80
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MK30DN512ZVLK10
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
but only one is performed at a given time as described ahead. The move-in starts only
when the message held by the Rx SMB has a corresponding matching winner (see
Section "Matching Process") and all of the following conditions are true:
The term pending move-in is used throughout the document and stands for a move-to-be
that still does not satisfy all of the aforementioned conditions.
The move-in is cancelled and the Rx SMB is able to receive another message if any of
the following conditions is satisfied:
Note that the pending move-in is not cancelled if the module enters Freeze or Low Power
Mode. It only stays on hold waiting for exiting Freeze and Low Pwer Mode and to be
unlocked. If an MB is unlocked during Freeze Mode, the move-in happens immediately.
The move-in process is the execution by the FlexCAN of the following steps:
Freescale Semiconductor, Inc.
1. if the message is destined to the Rx FIFO, push IDHIT into the RXFIR FIFO;
2. reads the words DATA0-3 and DATA4-7 from the Rx SMB;
3. writes it in the words DATA0-3 and DATA4-7 of the Rx Mailbox;
4. reads the words Control/Status and ID from the Rx SMB;
5. writes it in the words Control/Status and ID of the Rx Mailbox, updating the CODE
• the CAN bus has reached or let past either:
• there is no ongoing matching process;
• the destination Mailbox is not locked by the CPU;
• there is no ongoing move-in process from another Rx SMB. If more than one move-
• the destination Mailbox is inactivated after the CAN bus has reached the first bit of
• there is a previous pending move-in to the same destination Mailbox;
• the Rx SMB is receiving a frame transmitted by the FlexCAN itself and the self-
• any CAN protocol error is detected.
in processes are to be started at the same time both are performed and the newest
substitutes the oldest.
Intermission field next to the frame that carried the message and its matching process
has finished;
reception is disabled (MCR[SRXDIS] bit is asserted);
field.
• the second bit of Intermission field next to the frame that carried the message
• the first bit of an overload frame next to the frame that carried the message that
that is in the Rx SMB;
is in the Rx SMB;
K30 Sub-Family Reference Manual, Rev. 6, Nov 2011
Chapter 41 CAN (FlexCAN)
1045