HD6417727F100CV Renesas Electronics America, HD6417727F100CV Datasheet - Page 593

SH3-DSP, LEAD FREE

HD6417727F100CV

Manufacturer Part Number
HD6417727F100CV
Description
SH3-DSP, LEAD FREE
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417727F100CV

Core Processor
SH-3 DSP
Core Size
32-Bit
Speed
100MHz
Connectivity
FIFO, SCI, SIO, SmartCard, USB
Peripherals
DMA, LCD, POR, WDT
Number Of I /o
104
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.6 V ~ 2.05 V
Data Converters
A/D 6x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
240-QFP Exposed Pad, 240-eQFP, 240-HQFP
Cpu Family
SuperH
Device Core Size
32b
Frequency (max)
100MHz
Interface Type
SCI/USB
Program Memory Size
Not Required
Total Internal Ram Size
16KB
# I/os (max)
104
Number Of Timers - General Purpose
4
Operating Supply Voltage (typ)
1.8/3.3V
Operating Supply Voltage (max)
2.05/3.6V
Operating Supply Voltage (min)
1.6/2.6V
On-chip Adc
6-chx10-bit
On-chip Dac
2-chx8-bit
Instruction Set Architecture
RISC
Operating Temp Range
-20C to 75C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
240
Package Type
HQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
Compliant
In receiving, the SCI operates as follows:
1. The SCI synchronizes with serial clock input or output and initializes internally.
2. Receive data is shifted into the SCRSR in order from the LSB to the MSB. After receiving the
3. After setting RDRF to 1, if the receive-data-full interrupt enable bit (RIE) is set to 1 in the
Figure 17.22 shows an example of the SCI receive operation.
data, the SCI checks that RDRF is 0 so that receive data can be loaded from the SCRSR into
the SCRDR. If this check is passed, the SCI sets RDRF to 1 and stores the received data in the
SCRDR. If the check is not passed (receive error), the SCI operates as indicated in table 17.12.
This state prevents further transmission or reception. While receiving, the RDRF bit is not set
to 1. Be sure to clear the error flag.
SCSCR, the SCI requests a receive-data-full interrupt (RXI). If the ORER bit is set to 1 and the
receive-data-full interrupt enable bit (RIE) in the SCSCR is also set to 1, the SCI requests a
receive-error interrupt (ERI).
Figure 17.21 Sample Serial Reception Flowchart (2)
No
Clear ORER bit in SCSSR to 0
Overrun error processing
Error processing
ORER = 1?
Section 17 Serial Communication Interface (SCI)
End
Yes
Rev.6.00 Mar. 27, 2009 Page 535 of 1036
REJ09B0254-0600