HD6417727F100CV Renesas Electronics America, HD6417727F100CV Datasheet - Page 531

SH3-DSP, LEAD FREE

HD6417727F100CV

Manufacturer Part Number
HD6417727F100CV
Description
SH3-DSP, LEAD FREE
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417727F100CV

Core Processor
SH-3 DSP
Core Size
32-Bit
Speed
100MHz
Connectivity
FIFO, SCI, SIO, SmartCard, USB
Peripherals
DMA, LCD, POR, WDT
Number Of I /o
104
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.6 V ~ 2.05 V
Data Converters
A/D 6x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
240-QFP Exposed Pad, 240-eQFP, 240-HQFP
Cpu Family
SuperH
Device Core Size
32b
Frequency (max)
100MHz
Interface Type
SCI/USB
Program Memory Size
Not Required
Total Internal Ram Size
16KB
# I/os (max)
104
Number Of Timers - General Purpose
4
Operating Supply Voltage (typ)
1.8/3.3V
Operating Supply Voltage (max)
2.05/3.6V
Operating Supply Voltage (min)
1.6/2.6V
On-chip Adc
6-chx10-bit
On-chip Dac
2-chx8-bit
Instruction Set Architecture
RISC
Operating Temp Range
-20C to 75C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
240
Package Type
HQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
Compliant
16.3
16.3.1
All RTC registers should be set initially after the power is turned on.
16.3.2
Figures 16.2 (a) and 16.2 (b) show how to set the time after stopping the clock. This procedure can
be used to set the entire calendar and clock function. It can be programmed easily.
Usage Notes
1. Initialization Timing for 64 Hz Counter (R64CNT)
2. Incrementing RSECCNT by Initializing R64CNT
If it is necessary, after initializing the counter by means of the RESET bit in the RTC’s RCR2
register, to confirm that the change has taken effect by reading the R64CNT value, wait at least
107 µs after setting the RESET bit to 1 before reading the R64CNT counter. Note that the
divider circuit (RTC prescaler) is also initialized when the RESET bit is set to 1.
Either method (a) or method (b) below may be used.
(a) After setting the RESET bit to 1 and confirming that R64CNT has been initialized, set the
(b) Set the START bit to 1 and the RESET bit to 1 at the same time. This process is shown in
START bit to 1. This process is shown in figure 16.2 (a).
figure 16.2 (b). Note that the processing indicated by the asterisk (*) in figure 16.2 (b) may
be omitted if nothing is written to the RCR2 register during an interval of approximately
107 µs after the START bit is set to 1.
RTC Operation
Initial Settings of Registers after Power-On
Setting the Time
Rev.6.00 Mar. 27, 2009 Page 473 of 1036
Section 16 Realtime Clock (RTC)
REJ09B0254-0600