Table 5-42. Legacy Replacement Routing
®
I/O Controller Hub 6 (ICH6) Family Datasheet
High Precision Event Timers
This function provides a set of timers that can be used by the operating system. The timers are
defined such that in the future, the operating system may be able to assign specific timers to used
directly by specific applications. Each timer can be configured to cause a separate interrupt.
ICH6 provides three timers. The three timers are implemented as a single counter each with its own
comparator and value register. This counter increases monotonically. Each individual timer can
generate an interrupt when the value in its value register matches the value in the main counter.
The registers associated with these timers are mapped to a memory space (much like the I/O
APIC). However, it is not implemented as a standard PCI function. The BIOS reports to the
operating system the location of the register space. The hardware can support an assignable decode
space; however, the BIOS sets this space prior to handing it over to the operating system
(See
once it is set by the BIOS.
Timer Accuracy
The main counter is clocked by the 14.31818 MHz clock, synchronized into the 66.666 MHz
domain. This results in a non-uniform duty cycle on the synchronized clock, but does have the
correct average period. The accuracy of the main counter is as accurate as the 14.3818 MHz clock.
Interrupt Mapping
Mapping Option #1 (Legacy Replacement Option)
In this case, the Legacy Replacement Rout bit (LEG_RT_CNF) is set. This forces the mapping
found in
Mapping Option #2 (Standard Option)
In this case, the Legacy Replacement Rout bit (LEG_RT_CNF) is 0. Each timer has its own routing
control. The supported interrupt values are IRQ 20, 21, 22, and 23.
1. The timers are accurate over any 1 ms period to within 0.05% of the time specified in the timer
2. Within any 100 microsecond period, the timer reports a time that is up to two ticks too early or
3. The timer is monotonic. It does not return the same value on two consecutive reads (unless the
Timer
resolution fields.
too late. Each tick is less than or equal to 100 ns, so this represents an error of less than 0.2%.
counter has rolled over and reached the same value).
Section
0
1
2
Table
6.4). It is not expected that the operating system will move the location of these timers
Per IRQ Routing Field.
5-42.
8259 Mapping
IRQ0
IRQ8
Per IRQ Routing Field
APIC Mapping
IRQ2
IRQ8
In this case, the 8254 timer will not
cause any interrupts
In this case, the RTC will not cause any
interrupts.
Functional Description
Comment