R4F24278NVFQU Renesas Electronics America, R4F24278NVFQU Datasheet - Page 948

no-image

R4F24278NVFQU

Manufacturer Part Number
R4F24278NVFQU
Description
MCU 512K/48K 2.7-5.5V 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2400r
Datasheet

Specifications of R4F24278NVFQU

Core Processor
H8S/2600
Core Size
16/32-Bit
Speed
33MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, Smart Card, SPI, SSU, UART/USART
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
98
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Eeprom Size
-
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R4F24278NVFQU
Manufacturer:
REALTEK
Quantity:
2 300
Part Number:
R4F24278NVFQU
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 16 Serial Communication Interface (SCI, IrDA, CRC)
Page 918 of 1448
Bit
5
4
Bit Name
ORER
FER
0
0
Initial Value
R/W
R/(W) *
R/(W) *
Description
Overrun Error
Indicates that an overrun error occurred while
receiving and the reception has ended abnormally.
[Setting condition]
[Clearing condition]
Framing Error
Indicates that a framing error occurred while
receiving in asynchronous mode and the reception
has ended abnormally.
[Setting condition]
[Clearing condition]
When the next serial reception is completed
while RDRF = 1
The receive data prior to the overrun error is
retained in RDR, and the data received
subsequently is lost. Also, subsequent serial
reception cannot be continued while the ORER
flag is set to 1. In clocked synchronous mode,
serial transmission cannot be continued,
either.
When 0 is written to ORER after reading
ORER = 1
The ORER flag is not affected and retains its
previous state when the RE bit in SCR is
cleared to 0.
When the stop bit is 0
In 2-stop-bit mode, only the first stop bit is
checked for a value of 0; the second stop bit is
not checked. If a framing error occurs, the
receive data is transferred to RDR but the
RDRF flag is not set. Also, subsequent serial
reception cannot be continued while the FER
flag is set to 1. In clocked synchronous mode,
serial transmission cannot be continued,
either.
When 0 is written to FER after reading FER =
1
The FER flag is not affected and retains its
previous state when the RE bit in SCR is
cleared to 0.
H8S/2427, H8S/2427R, H8S/2425 Group
REJ09B0565-0100 Rev. 1.00
Jul 22, 2010

Related parts for R4F24278NVFQU