R4F24278NVFQU Renesas Electronics America, R4F24278NVFQU Datasheet - Page 141

no-image

R4F24278NVFQU

Manufacturer Part Number
R4F24278NVFQU
Description
MCU 512K/48K 2.7-5.5V 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2400r
Datasheet

Specifications of R4F24278NVFQU

Core Processor
H8S/2600
Core Size
16/32-Bit
Speed
33MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, Smart Card, SPI, SSU, UART/USART
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
98
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Eeprom Size
-
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R4F24278NVFQU
Manufacturer:
REALTEK
Quantity:
2 300
Part Number:
R4F24278NVFQU
Manufacturer:
Renesas Electronics America
Quantity:
10 000
H8S/2427, H8S/2427R, H8S/2425 Group
5.6
Trap instruction exception handling starts when a TRAPA instruction is executed. Trap instruction
exception handling can be executed at all times in the program execution state.
The trap instruction exception handling is as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended register
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. A vector address corresponding to the interrupt source is generated, the start address is loaded
The TRAPA instruction fetches a start address from a vector table entry corresponding to a vector
number from 0 to 3, as specified in the instruction code.
Table 5.4 shows the status of CCR and EXR after execution of trap instruction exception handling.
Table 5.4
Legend:
1:
0:
⎯: Retains value prior to execution
REJ09B0565-0100 Rev. 1.00
Jul 22, 2010
Interrupt Control Mode
0
2
(EXR) are saved in the stack.
from the vector table to the PC, and program execution starts from that address.
Set to 1
Cleared to 0
Trap Instruction Exception Handling
Status of CCR and EXR after Trap Instruction Exception Handling
I
1
1
CCR
UI
I2 to I0
Section 5 Exception Handling
EXR
T
0
Page 111 of 1448