R4F24278NVFQU Renesas Electronics America, R4F24278NVFQU Datasheet - Page 1244

no-image

R4F24278NVFQU

Manufacturer Part Number
R4F24278NVFQU
Description
MCU 512K/48K 2.7-5.5V 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2400r
Datasheet

Specifications of R4F24278NVFQU

Core Processor
H8S/2600
Core Size
16/32-Bit
Speed
33MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, Smart Card, SPI, SSU, UART/USART
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
98
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Eeprom Size
-
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R4F24278NVFQU
Manufacturer:
REALTEK
Quantity:
2 300
Part Number:
R4F24278NVFQU
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 25 Clock Pulse Generator
25.3
The system-clock PLL circuit and divider have the function of multiplying the frequency of the
clock from the oscillator by a factor of 1, 2, or dividing by 2. The system clock frequency is set
with the STC1 and STC0 bits in PLLCR. The phase of the rising edge of the internal clock is
controlled so as to match that of the rising edge of the EXTAL pin.
When the frequency is changed with the system-clock PLL circuit and divider, operation varies
according to the setting of the STCS bit in SCKCR.
When STCS = 0, the setting of the changed frequency becomes valid after a transition to software
standby mode. The transition time count is performed in accordance with the setting of bits STS3
to STS0 in SBYCR. For details on SBYCR, see section 26.1.1, Standby Control Register
(SBYCR).
1. The initial PLL circuit multiplication factor is 1.
2. A value is set in bits STS3 to STS0 to give the specified transition time.
3. The target value is set in bits STC1 and STC0, and a transition is made to software standby
4. The clock pulse generator stops and the value set in STC1 and STC0 becomes valid.
5. Software standby mode is cleared, and a transition time is secured in accordance with the
6. After the set transition time has elapsed, this LSI resumes operation using the target
When STCS = 1, a change to the frequency setting becomes effective a maximum of four cycles
after the setting is changed. If the clock frequency is changed during access to an external address
space, correct operation cannot be guaranteed. Therefore, be sure to store instructions that change
the STC1 and STC0 bits and other instructions to be executed within a maximum of four cycles
after the change to the frequency setting in on-chip ROM or on-chip RAM, so that instructions do
not access an external address space before the frequency clock is switched over.
Page 1214 of 1448
mode.
setting in STS3 to STS0.
multiplication factor.
System-Clock PLL Circuit and Divider
H8S/2427, H8S/2427R, H8S/2425 Group
REJ09B0565-0100 Rev. 1.00
Jul 22, 2010