UPD78F1174AGF-GAT-AX Renesas Electronics America, UPD78F1174AGF-GAT-AX Datasheet - Page 935

no-image

UPD78F1174AGF-GAT-AX

Manufacturer Part Number
UPD78F1174AGF-GAT-AX
Description
MCU 16BIT 78K0R/KX3 128-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Kx3r
Datasheet

Specifications of UPD78F1174AGF-GAT-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, EBI/EMI, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
111
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F1174AGF-GAT-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Serial
interface
IIC0
DMA
controller
Function
When STCEN =
0
When STCEN =
1
If other I
communications
are already in
progress
Setting transfer
clock frequency
STT0, SPT0:
Bits 1, 0 of IIC
control register 0
(IICC0)
Reserving
transmission
DBCn: DMA
byte count
register n
Details of
Function
2
C
Immediately after I
(IICBSY (bit 6 of IICF0) = 1) is recognized regardless of the actual bus status. When
changing from a mode in which no stop condition has been detected to a master
device communication mode, first generate a stop condition to release the bus, then
perform master device communication.
When using multiple masters, it is not possible to perform master device
communication when the bus has not been released (when a stop condition has not
been detected).
Use the following sequence for generating a stop condition.
<1> Set IIC clock select register 0 (IICCL0).
<2> Set bit 7 (IICE0) of IIC control register 0 (IICC0) to 1.
<3> Set bit 0 (SPT0) of IICC0 to 1.
Immediately after I
(IICBSY = 0) is recognized regardless of the actual bus status. To generate the first
start condition (STT0 (bit 1 of IIC control register 0 (IICC0)) = 1), it is necessary to
confirm that the bus has been released, so as to not disturb other communications.
If I
progress when the SDA0 pin is low and the SCL0 pin is high, the macro of I
recognizes that the SDA0 pin has gone low (detects a start condition). If the value on
the bus at this time can be recognized as an extension code, ACK is returned, but
this interferes with other I
sequence.
<1> Clear bit 4 (SPIE0) of IICC0 to 0 to disable generation of an interrupt request
<2> Set bit 7 (IICE0) of IICC0 to 1 to enable the operation of I
<3> Wait for detection of the start condition.
<4> Set bit 6 (LREL0) of IICC0 to 1 before ACK is returned (4 to 80 clocks after
Determine the transfer clock frequency by using SMC0, CL01, CL00 (bits 3, 1, and 0
of IICL0), and CLX0 (bit 0 of IICX0) before enabling the operation (IICE0 = 1). To
change the transfer clock frequency, clear IICE0 to 0 once.
Setting STT0 and SPT0 (bits 1 and 0 of IICC0) again after they are set and before
they are cleared to 0 is prohibited.
When transmission is reserved, set SPIE0 (bit 4 of IICL0) to 1 so that an interrupt
request is generated when the stop condition is detected. Transfer is started when
communication data is written to IIC0 after the interrupt request is generated. Unless
the interrupt is generated when the stop condition is detected, the device stops in the
wait state because the interrupt request is not generated when communication is
started. However, it is not necessary to set SPIE0 to 1 when MSTS0 (bit 7 of IICS0)
is detected by software.
Be sure to clear bits 15 to 10 to “0”.
If the general-purpose register is specified or the internal RAM space is exceeded as
a result of continuous transfer, the general-purpose register or SFR space are written
or read, resulting in loss of data in these spaces. Be sure to set the number of times
of transfer that is within the internal RAM space.
2
C operation is enabled and the device participates in communication already in
signal (INTIIC0) when the stop condition is detected.
setting IICE0 to 1), to forcibly disable detection.
APPENDIX B LIST OF CAUTIONS
User’s Manual U18432EJ5V0UD
2
C operation is enabled (IICE0 = 1), the bus communication status
2
C operation is enabled (IICE0 = 1), the bus released status
2
C communications. To avoid this, start I
Cautions
2
C.
2
C in the following
2
C
p.591
p.591
p.591
p.591
p.591
p.591
p.634
p.634
(21/35)
933
Page