UPD78F1174AGF-GAT-AX Renesas Electronics America, UPD78F1174AGF-GAT-AX Datasheet - Page 314

no-image

UPD78F1174AGF-GAT-AX

Manufacturer Part Number
UPD78F1174AGF-GAT-AX
Description
MCU 16BIT 78K0R/KX3 128-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Kx3r
Datasheet

Specifications of UPD78F1174AGF-GAT-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, EBI/EMI, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
111
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F1174AGF-GAT-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
312
TMRmn
TOMm
TOEm
TOLm
TOm
Remark
Figure 7-59. Example of Set Contents of Registers When PWM Function (Master Channel) Is Used
(a) Timer mode register mn (TMRmn)
(b) Timer output register m (TOm)
(c) Timer output enable register m (TOEm)
(d) Timer output level register m (TOLm)
(e) Timer output mode register m (TOMm)
TOMmn
TOEmn
CKSmn
TOLmn
TOmn
Bit n
Bit n
Bit n
Bit n
1/0
15
0
0
0
0
When m = 0: n = 0, 2, 4, 6
When m = 1: n = 0, 2
m: Unit number, n: Channel number
Operation clock selection
14
0: Selects CKm0 as operation clock of channel n.
1: Selects CKm1 as operation clock of channel n.
0
0: Outputs 0 from TOmn.
0: Stops the TOmn output operation by counting operation.
0: Cleared to 0 when TOMmn = 0 (toggle mode).
0: Sets toggle mode.
13
0
CCSmn
12
0
Count clock selection
TERmn
MAS
11
0: Selects operation clock.
1
CHAPTER 7 TIMER ARRAY UNIT
Slave/master selection
STSmn2
10
1: Master channel
0
User’s Manual U18432EJ5V0UD
STSmn1
9
0
Start trigger selection
STSmn0
000B: Selects only software start.
8
0
CISmn1
0
7
CISmn0
6
0
Selection of TImn pin input edge
00B: Sets 00B because these are not used.
Operation mode of channel n
000B: Interval timer
0
5
Setting of operation when counting is started
1: Generates INTTMmn when counting is
started.
4
0
MDmn3
3
0
MDmn2
2
0
MDmn1
1
0
MDmn0
0