UPD78F1174AGF-GAT-AX Renesas Electronics America, UPD78F1174AGF-GAT-AX Datasheet - Page 443

no-image

UPD78F1174AGF-GAT-AX

Manufacturer Part Number
UPD78F1174AGF-GAT-AX
Description
MCU 16BIT 78K0R/KX3 128-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Kx3r
Datasheet

Specifications of UPD78F1174AGF-GAT-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, EBI/EMI, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
111
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F1174AGF-GAT-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
13.4 Operation stop mode
P11/SI00/RxD0/EX25, P12/SO00/TxD0/EX26, P13/TxD3/EX27, P14/RxD3/EX28, P43/SCK01, P44/SI01, P45/SO01,
P95/SCK11/SCL11,
P142/SCK20/SCL20, P143/SI20/SDA20/RxD2, or P144/SO20/TxD2 pin can be used as ordinary port pins in this
mode.
13.4.1 Stopping the operation by units
is not used is stopped in order to reduce the power consumption and noise.
Each serial interface of serial array unit has the operation stop mode.
In this mode, serial communication cannot be executed, thus reducing the power consumption.
In
The stopping of the operation by units is set by using peripheral enable register 0 (PER0).
PER0 is used to enable or disable use of each peripheral hardware macro. Clock supply to a hardware macro that
To stop the operation of serial array unit 0, set bit 2 (SAU0EN) to 0.
To stop the operation of serial array unit 1, set bit 3 (SAU1EN) to 0.
PER0
Figure 13-22. Peripheral Enable Register 0 (PER0) Setting When Stopping the Operation by Units
Caution
Remark
addition,
(a) Peripheral enable register 0 (PER0) … Set only the bit of SAUm to be stopped to 0.
RTCEN
×
7
m: Unit number (m = 0, 1)
×: Bits not used with serial array units (depending on the settings of other peripheral functions)
0/1: Set to 0 or 1 depending on the usage of the user
If SAUmEN = 0, writing to a control register of serial array unit m is ignored, and, even if the
register is read, only the default value is read (except for input switch control register (ISC),
noise filter enable register (NFEN0), port input mode registers (PIM0, PIM4, PIM9, PIM12,
PIM14), port output mode registers (POM0, POM4, POM9, POM12, POM14), port mode
registers (PM0, PM1, PM4, PM9, PM12, PM14), and port registers (P0, P1, P4, P9, P12, P14)).
the
P96/SI11/SDA11,
P02/SO10/TxD1,
DACEN
6
×
Control of SAUm input clock
0: Stops supply of input clock
1: Supplies input clock
ADCEN
CHAPTER 13 SERIAL ARRAY UNIT
×
5
P97/SO11,
User’s Manual U18432EJ5V0UD
P03/SI10/SDA10/RxD1,
IIC0EN
4
×
P125/SCK21/SCL21,
SAU1EN
0/1
3
P04/SCK10/SCL10,
SAU0EN
0/1
2
P126/SI21/SDA21,
TAU0EN
1
×
P10/SCK00/EX24,
TAU0EN
0
×
P127/SO21,
441