ATSAM3S1BA-AU Atmel, ATSAM3S1BA-AU Datasheet - Page 930

IC MCU 32BIT 64KB FLASH 64LQFP

ATSAM3S1BA-AU

Manufacturer Part Number
ATSAM3S1BA-AU
Description
IC MCU 32BIT 64KB FLASH 64LQFP
Manufacturer
Atmel
Series
SAM3Sr
Datasheets

Specifications of ATSAM3S1BA-AU

Core Processor
ARM® Cortex-M3™
Core Size
32-Bit
Speed
64MHz
Connectivity
I²C, MMC, SPI, SSC, UART/USART, USB
Peripherals
Brown-out Detect/Reset, DMA, I²S, POR, PWM, WDT
Number Of I /o
47
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.62 V ~ 1.95 V
Data Converters
A/D 10x10/12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-LQFP
Controller Family/series
ATSAM3S
No. Of I/o's
47
Ram Memory Size
16KB
Cpu Speed
64MHz
No. Of Timers
6
Rohs Compliant
Yes
Processor Series
ATSAM3x
Core
ARM Cortex M3
3rd Party Development Tools
JTRACE-CM3, MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
ATSAM3S-EK
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATSAM3S1BA-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATSAM3S1BA-AUR
Manufacturer:
Atmel
Quantity:
10 000
37.6.1.3
930
SAM3S Preliminary
USB Transfer Event Definitions
As indicated below, transfers are sequential events carried out on the USB bus.
Table 37-5.
Notes:
A status transaction is a special type of host-to-device transaction used only in a control transfer.
The control transfer must be performed using endpoints with no ping-pong attributes. According
to the control sequence (read or write), the USB device sends or receives a status transaction.
Control Transfers
Interrupt IN Transfer
(device toward host)
Interrupt OUT Transfer
(host toward device)
Isochronous IN Transfer
(device toward host)
Isochronous OUT Transfer
(host toward device)
Bulk IN Transfer
(device toward host)
Bulk OUT Transfer
(host toward device)
1. Setup Transaction
2. Data IN Transaction
3. Data OUT Transaction
1. Control transfer must use endpoints with no ping-pong attributes.
2. Isochronous transfers must use endpoints with ping-pong attributes.
3. Control transfers can be aborted using a stall handshake.
USB Transfer Events
(1) (3)
(2)
(2)
• Setup transaction > Data IN transactions > Status
• Setup transaction > Data OUT transactions > Status
• Setup transaction > Status IN transaction
• Data IN transaction > Data IN transaction
• Data OUT transaction > Data OUT transaction
• Data IN transaction > Data IN transaction
• Data OUT transaction > Data OUT transaction
• Data IN transaction > Data IN transaction
• Data OUT transaction > Data OUT transaction
OUT transaction