DF61654N50FTV Renesas Electronics America, DF61654N50FTV Datasheet - Page 793

IC H8SX/1654 MCU FLASH 120TQFP

DF61654N50FTV

Manufacturer Part Number
DF61654N50FTV
Description
IC H8SX/1654 MCU FLASH 120TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8SX/1600r
Datasheet

Specifications of DF61654N50FTV

Core Processor
H8SX
Core Size
32-Bit
Speed
50MHz
Connectivity
I²C, IrDA, SCI, SmartCard, USB
Peripherals
DMA, PWM, WDT
Number Of I /o
75
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
120-TQFP, 120-VQFP
For Use With
HS0005KCU11H - EMULATOR E10A-USB H8S(X),SH2(A)3DK1657 - DEV EVAL KIT FOR H8SX/1657
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF61654N50FTV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
17.4.2
In scan mode, A/D conversion is to be performed sequentially on the analog inputs of the specified
channels up to four or eight channels.
1. When the ADST bit in ADCSR is set to 1 by software, TPU, TMR, or an external trigger
2. When A/D conversion for each channel is completed, the A/D conversion result is sequentially
ADIE
ADST
ADF
Channel 0 (AN0)
operation state
Channel 1 (AN1)
operation state
Channel 2 (AN2)
operation state
Channel 3 (AN3)
operation state
ADDRA
ADDRB
ADDRC
ADDRD
input, A/D conversion starts on the first channel in the group. Consecutive A/D conversion on
a maximum of four channels (SCANE and SCANS = B'10) or on a maximum of eight
channels (SCANE and SCANS = B'11) can be selected. When consecutive A/D conversion is
performed on four channels, A/D conversion starts on AN4 when CH3 and CH2 = B'01. When
consecutive A/D conversion is performed on eight channels, A/D conversion starts on AN0
when CH3 = B'0.
transferred to the corresponding ADDR of each channel.
Figure 17.2 Example of A/D Converter Operation (Single Mode, Channel 1 Selected)
Note: *
Scan Mode
A/D conversion start
indicates the timing of instruction execution by software.
Waiting for
conversion
Waiting for conversion
Waiting for conversion
Waiting for conversion
Set
Set
A/D conversion 1
*
*
Waiting for conversion
Clear
Reading A/D conversion result
A/D conversion result 1
*
Set
A/D conversion 2
Rev.1.00 Sep. 08, 2005 Page 743 of 966
*
Section 17 A/D Converter
Reading A/D conversion result
A/D conversion result 2
Waiting for conversion
Clear
REJ09B0219-0100
*