HD6413007F20 Renesas Electronics America, HD6413007F20 Datasheet - Page 83

IC H8 MCU ROMLESS 5V 100QFP

HD6413007F20

Manufacturer Part Number
HD6413007F20
Description
IC H8 MCU ROMLESS 5V 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD6413007F20

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
35
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413007F20V
Manufacturer:
RENESAS-Pb free
Quantity:
2
2.8.4
Reset Exception Handling: Reset exception handling has the highest priority. The reset state is
entered when the RES signal goes low. Reset exception handling starts after that, when RES
changes from low to high. When reset exception handling starts the CPU fetches a start address
from the exception vector table and starts program execution from that address. All interrupts,
including NMI, are disabled during the reset exception-handling sequence and immediately after it
ends.
Interrupt Exception Handling and Trap Instruction Exception Handling: When these
exception-handling sequences begin, the CPU references the stack pointer (ER7) and pushes the
program counter and condition code register on the stack. Next, if the UE bit in the system control
register (SYSCR) is set to 1, the CPU sets the I bit in the condition code register to 1. If the UE bit
is cleared to 0, the CPU sets both the I bit and the UI bit in the condition code register to 1. Then
the CPU fetches a start address from the exception vector table and execution branches to that
address.
Figure 2.14 shows the stack after the exception-handling sequence.
SP (ER7)
Legend:
CCR:
SP:
Notes: 1.
SP−4
SP−3
SP−2
SP−1
Exception-Handling Sequences
Condition code register
Stack pointer
2.
PC is the address of the first instruction executed after the return from the
exception-handling routine.
Registers must be saved and restored by word access or longword access,
starting at an even address.
Figure 2.14 Stack Structure after Exception Handling
Before exception
handling starts
Stack area
Pushed on stack
SP (ER7)
SP+1
SP+2
SP+3
SP+4
Rev.5.00 Sep. 12, 2007 Page 53 of 764
After exception
handling ends
CCR
PC
REJ09B0396-0500
Even
address
2. CPU

Related parts for HD6413007F20