HD6413007F20 Renesas Electronics America, HD6413007F20 Datasheet - Page 528

IC H8 MCU ROMLESS 5V 100QFP

HD6413007F20

Manufacturer Part Number
HD6413007F20
Description
IC H8 MCU ROMLESS 5V 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD6413007F20

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
35
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413007F20V
Manufacturer:
RENESAS-Pb free
Quantity:
2
14. Smart Card Interface
14.3.4
Table 14.3 shows a bit map of the registers used in the smart card interface. Bits indicated as 0 or
1 must be set to the value shown. The setting of other bits is described in this section.
Table 14.3 Smart Card Interface Register Settings
Register Address*
SMR
BRR
SCR
TDR
SSR
RDR
SCMR
Notes: ⎯ Unused bit.
Serial Mode Register (SMR) Settings: Clear the GM bit to 0 when using the normal smart card
interface mode, or set to 1 when using GSM mode. Clear the O/E bit to 0 if the smart card is of the
direct convention type, or set to 1 if of the inverse convention type.
Bits CKS1 and CKS0 select the clock source of the built-in baud rate generator. See section
14.3.5, Clock.
Bit Rate Register (BRR) Settings: BRR is used to set the bit rate. See section 14.3.5, Clock, for
the method of calculating the value to be set.
Serial Control Register (SCR) Settings: The TIE, RIE, TE, and RE bits have their normal serial
communication functions. See section 13, Serial Communication Interface, for details. The CKE1
and CKE0 bits specify clock output. To disable clock output, clear these bits to 00; to enable clock
output, set these bits to 01. Clock output is not performed when the GM bit is set to 1 in SMR.
Clock output can also be fixed low or high.
Smart Card Mode Register (SCMR) Settings: Clear both the SDIR bit and SINV bit cleared to
0 if the smart card is of the direct convention type, and set both to 1 if of the inverse convention
type. To use the smart card interface, set the SMIF bit to 1.
Rev.5.00 Sep. 12, 2007 Page 498 of 764
REJ09B0396-0500
1. Lower 20 bits of the address in advanced mode.
2. When GM is cleared to 0 in SMR, the CKE1 bit must also be cleared to 0.
Register Settings
H'FFFB0
H'FFFB1
H'FFFB2
H'FFFB3
H'FFFB4
H'FFFB5
H'FFFB6
1
Bit 7
GM
BRR7
TIE
TDR7
TDRE
RDR7
Bit 6
0
BRR6
RIE
TDR6
RDRF
RDR6
Bit 5
1
BRR5
TE
TDR5
ORER
RDR5
Bit 4
O/E
BRR4
RE
TDR4
ERS
RDR4
Bit
Bit 3
1
BRR3
0
TDR3
PER
RDR3
SDIR
Bit 2
0
BRR2
0
TDR2
RDR2
SINV
TEND
CKS1
Bit 1
BRR1
CKE1*
TDR1
0
RDR1
2
Bit 0
CKS0
BRR0
CKE0
TDR0
0
RDR0
SMIF

Related parts for HD6413007F20