HD6413007F20 Renesas Electronics America, HD6413007F20 Datasheet - Page 489

IC H8 MCU ROMLESS 5V 100QFP

HD6413007F20

Manufacturer Part Number
HD6413007F20
Description
IC H8 MCU ROMLESS 5V 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD6413007F20

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
35
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413007F20V
Manufacturer:
RENESAS-Pb free
Quantity:
2
Clock: An internal clock generated by the on-chip baud rate generator or an external clock input
from the SCK pin can be selected as the SCI transmit/receive clock. The clock source is selected
by the C/A bit in SMR and bits CKE1 and CKE0 in SCR. For details of SCI clock source
selection, see table 13.9.
When an external clock is input at the SCK pin, it must have a frequency 16 times the desired bit
rate.
When the SCI is operated on an internal clock, it can output a clock signal at the SCK pin. The
frequency of this output clock is equal to the bit rate. The phase is aligned as shown in figure 13.3
so that the rising edge of the clock occurs at the center of each transmit data bit.
Transmitting and Receiving Data:
• SCI Initialization (Asynchronous Mode): Before transmitting or receiving data, clear the TE
and RE bits to 0 in SCR, then initialize the SCI as follows.
When changing the communication mode or format, always clear the TE and RE bits to 0
before following the procedure given below. Clearing TE to 0 sets the TDRE flag to 1 and
initializes TSR. Clearing RE to 0, however, does not initialize the RDRF, PER, FER, and
ORER flags, or RDR, which retain their previous contents.
When an external clock is used the clock should not be stopped during initialization or
subsequent operation, since operation will be unreliable in this case.
Figure 13.4 shows a sample flowchart for initializing the SCI.
0
Figure 13.3 Phase Relationship between Output Clock and Serial Data
D0
D1
D2
D3
(Asynchronous Mode)
1 frame
D4
D5
D6
D7
Rev.5.00 Sep. 12, 2007 Page 459 of 764
13. Serial Communication Interface
0/1
1
1
REJ09B0396-0500

Related parts for HD6413007F20