HD6413007F20 Renesas Electronics America, HD6413007F20 Datasheet - Page 500

IC H8 MCU ROMLESS 5V 100QFP

HD6413007F20

Manufacturer Part Number
HD6413007F20
Description
IC H8 MCU ROMLESS 5V 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD6413007F20

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
35
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413007F20V
Manufacturer:
RENESAS-Pb free
Quantity:
2
13. Serial Communication Interface
• Receiving Multiprocessor Serial Data: Figure 13.12 shows a sample flowchart for receiving
Rev.5.00 Sep. 12, 2007 Page 470 of 764
REJ09B0396-0500
multiprocessor serial data and indicates the procedure to follow.
Figure 13.12 Sample Flowchart for Receiving Multiprocessor Serial Data (1)
No
No
No
Read ORER and FER flags
Read ORER and FER flags
Read receive data from RDR
Set MPIE bit to 1 in SCR
Clear RE bit to 0 in SCR
Read RDRF flag in SSR
Read RDRF flag in SSR
Read RDRF flag in SSR
Finished receiving?
FER∨ORER = 1
FER∨ORER = 1
Start receiving
RDRF = 1
RDRF = 1
Own ID?
Initialize
in SSR
in SSR
<End>
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
Error handling
(1)
(2)
(3)
(continued on next page)
(5)
(4)
(1)
(2)
(3)
(4)
(5)
SCI initialization:
the receive data input function of the
RxD pin is selected automatically.
ID receive cycle:
set the MPIE bit to 1 in SCR.
SCI status check and ID check:
read SSR, check that the RDRF flag
is set to 1, then read data from RDR
and compare it with the processor's
own ID. If the ID does not match, set
the MPIE bit to 1 again and clear the
RDRF flag to 0. If the ID matches,
clear the RDRF flag to 0.
SCI status check and data receiving:
read SSR, check that the RDRF flag
is set to 1, then read data from RDR.
Receive error handling and break
detection:
if a receive error occurs, read the
ORER and FER flags in SSR to
identify the error. After executing the
necessary error handling, clear the
ORER and FER flags both to 0.
Receiving cannot resume while either
the ORER or FER flag remains set to
1. When a framing error occurs, the
RxD pin can be read to detect the
break state.

Related parts for HD6413007F20