HD6413007F20 Renesas Electronics America, HD6413007F20 Datasheet - Page 555

IC H8 MCU ROMLESS 5V 100QFP

HD6413007F20

Manufacturer Part Number
HD6413007F20
Description
IC H8 MCU ROMLESS 5V 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD6413007F20

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
35
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413007F20V
Manufacturer:
RENESAS-Pb free
Quantity:
2
15.4.2
Scan mode is useful for monitoring analog inputs in a group of one or more channels. When the
ADST bit is set to 1 by software or external trigger input, A/D conversion starts on the first
channel in the group (AN
selected, after conversion of the first channel ends, conversion of the second channel (AN
starts immediately. A/D conversion continues cyclically on the selected channels until the ADST
bit is cleared to 0. The conversion results are transferred for storage into the A/D data registers
corresponding to the channels.
When the mode or analog input channel selection must be changed during analog conversion, to
prevent incorrect operation, first clear the ADST bit to 0 in ADCSR to halt A/D conversion. After
making the necessary changes, set the ADST bit to 1. A/D conversion will start again from the
first channel in the group. The ADST bit can be set at the same time as the mode or channel
selection is changed.
Typical operations when three channels in group 0 (AN
described next. Figure 15.4 shows a timing diagram for this example.
1. Scan mode is selected (SCAN = 1), scan group 0 is selected (CH2 = 0), analog input channels
2. When A/D conversion of the first channel (AN
3. Conversion proceeds in the same way through the third channel (AN
4. When conversion of all selected channels (AN
5. Steps 2 to 4 are repeated as long as the ADST bit remains set to 1. When the ADST bit is
AN
ADDRA. Next, conversion of the second channel (AN
and conversion of the first channel (AN
interrupt is requested at this time.
cleared to 0, A/D conversion stops. After that, if the ADST bit is set to 1, A/D conversion
starts again from the first channel (AN
0
to AN
Scan Mode (SCAN = 1)
2
are selected (CH1 = 1, CH0 = 0), and A/D conversion is started (ADST = 1).
0
when CH2 = 0, AN
0
).
0
) starts again. If the ADIE bit is set to 1, an ADI
4
when CH2 = 1). When two or more channels are
0
0
) is completed, the result is transferred into
to AN
0
to AN
Rev.5.00 Sep. 12, 2007 Page 525 of 764
2
1
) is completed, the ADF flag is set to 1
) starts automatically.
2
) are selected in scan mode are
2
).
15. A/D Converter
REJ09B0396-0500
1
or AN
5
)

Related parts for HD6413007F20