Revision 1.07
Embedded Controller Modules
When transitioning from SuperI/O Enabled PMC Enabled state, there may be a transition period in which the core domain
clock is still toggling according to the setting in SuperI/O Enabled PMC Enabled state. This occurs until software method 1
is performed by the interrupt handler of the SuperI/O Disabled event.
Transition to SuperI/O Enabled PMC Disabled State
Transition to SuperI/O Enabled PMC Enabled State
When transitioning from PMC Enabled SuperI/O Disabled state, there may be a transition period in which the core domain
clock is still toggling according to the setting in PMC Enabled SuperI/O Disabled state. This occurs until software method 2
is performed by the interrupt handler of the SuperI/O Enabled event. During this transition period, the host domain clock is
still disabled.
4.18.6 48 MHz Clock Monitor
While in one of the SuperI/O Enabled states, a WATCHDOG reset or Debugger Interface reset does not interfere with the
operation of the SuperI/O. Thus, if the 48 MHz clock is correctly toggling, it is not interfered with. Toggling is monitored by
the 48 MHz clock monitor. If a violation is detected, the 48 MHz monitor error flag is set and the HFCG goes through a com-
plete reset, after which it is put into PMC Enabled SuperI/O Disabled state, ignoring the host domain enable signal.
The 48 MHz clock monitor is initiated when a WATCHDOG reset or Debugger Interface reset occurs while the HFCG is in
a SuperI/O Enabled state. The monitor checks that the host domain clock frequency is in the range of 48 MHz 1%.
If the host domain clock frequency is in the correct range, the HFCG continues generating the 96 MHz OSCCLK, but the
programmable pre-scaler is set to a default of divide by 24. The HFCG is in SuperI/O Enabled PMC Enabled state.
The core reset routine is responsible for switching to SuperI/O Enabled PMC Enabled state and/or communicating the failure
to the host software.
4.18.7 HFCG Registers
For a summary of the abbreviations used for Register Type, see “Register Abbreviations and Access” on page 34.
HFCG Register Map
OSCCLK defaults to 96 MHz
The host domain clock is enabled and starts toggling as soon as the frequency multiplier has stabilized
The core domain clock is disabled (low)
When transitioning from SuperI/O Enabled PMC Disabled state:
— OSCCLK defaults to 96 MHz
— The pre-scaler is set according to HFCGP
When transitioning from PMC Enabled SuperI/O Disabled state:
— Software sets OSCCLK and the pre-scaler by the LOAD96 or FAST96 command (software method 2)
The host domain clock is enabled and starts toggling as soon as the frequency multiplier has stabilized
The core domain clock is enabled and starts toggling as soon as the frequency multiplier has stabilized
HFCGCTRL1 HFCG Control 1
HFCGML
HFCGMH
HFCGN
HFCGIL
HFCGIH
HFCGP
HFCGCTRL2 HFCG Control 2
Mnemonic
M Low Byte Value
M High Byte Value
N Value
I Low Byte Value
I High Byte Value
HFCG Pre-Scaler
(Continued)
Register Name
243
Varies per bit
Varies per bit
Type
R/W
R/W
R/W
R/W
R/W
R/W
www.national.com