XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 64

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
Function Tables Arranged by Purpose
Operation with
highly precise
timing
Timing output
according to
workpiece posi-
tion
Purpose
Increasing accu-
racy of external
output ON time.
(Feeding, hole
opening, tape
winding, gluing,
and other appli-
cations)
Highly accurate
measurement of
external input
signal ON/OFF
time
Various pro-
cessing (instruc-
tion execution)
at each one of
multiple time
intervals, using
high-precision
timer
Timing output
using high-
speed counter
PV
High-precision
ON outputs, with
minimum unit of
0.01 ms
Starting/stop-
ping high-preci-
sion timer at
0.001-ms unit
min.
Outputting
ON/OFF pat-
tern when pulse
output counter
PV is within set
value range.
Outputting
ON/OFF pat-
tern when high-
speed counter
PV within cer-
tain range
Operation
• One-shot pulse
• Pulse output
• Pulse output
• Range com-
• High-speed
Main functions
outputs
(STIM(980)
instruction)
counter mea-
surement
mode (time
measurement)
(Unit: 0.001 ms
min.)
counter mea-
surement
mode (time
measurement)
parison bit pat-
tern output
counter range
comparison bit
pattern output
(Executes
comparison at
execution of
CTBL(882)
instructions)
used
7-5 Pulse Inputs
Set pulse output operation mode to one-shot
output.
Specified outputs turn ON during specified inter-
val (0.01 ms to 9,999 ms).
Output OFF after specified time elapses is per-
formed by hardware, which gives accurate ON
time with no fluctuation.
Can be used within interrupt tasks because uses
special timer.
7-6-8 Time Measurement with the Pulse
Counter
Time measurement starts/stops with input inter-
rupt (MSKS(690) instruction) + STIM(980)
instruction within interrupt tasks. The elapsed
time is stored in Motion Control Module Auxiliary
Area. This data can be read using the PRV
instruction.
Note Pulse output 1 or pulse output 2 must be
7-6-8 Time Measurement with the Pulse
Counter
Can be used to obtain output pattern each time
interval elapsed after timer start.
Timer accuracy can be selected from as low as
0.001 ms.
7-5-8 Pulse Input Function Description
Outputs set bit pattern when high-speed counter
PV enters the range between set upper and
lower limits.
set to pulse counter time measurement in
System Setup.
Details
Section 1-7
37