Procedure
Mode 2 Procedure
Procedure
7-5-10 Pulse Input Function Example Application
Example 1:
High-speed Counter
Target Value
Comparison Interrupt
Pulse Inputs
1,2,3...
1,2,3...
1,2,3...
2. Wire the input.
3. Make the necessary System Setup settings.
4. Create the necessary ladder programming.
1. Set Counter movements (mode 1) in the System Settings (Pulse Input,
2. Turn ON the Measurement Start Bit (A860.02 or A861.02).
3. Monitor the high-speed counter movement value in A854 and A855
1. Determine the Counting Speed, Input Mode, Reset Method, and Counter
2. Wire the input.
3. Make the necessary System Setup settings.
4. Create the necessary ladder programming.
1. Set Frequency measurement (mode 2) in the System Settings (Pulse In-
2. Specify the rotation direction in the Measurement Direction Bit (A860.03).
3. Turn ON the Measurement Start Bit (A860.02).
4. Monitor the high-speed counter’s frequency in A854 and A855.
In this example, pulse input 1 operates a high-speed counter, the high-speed
counter PV is compared in a target-value comparison, and corresponding
interrupt tasks are executed when the target values are reached.
• Counter Data Display: Counter movements (mode 1)
• Turn ON the High-speed Counter 1 or 2 Start Bit (A860.00 or A861.00)
• Turn ON the Measurement Start Bit (A860.02 or A861.02).
• Monitor the high-speed counter movement value in A854 and A855
• Counting Speed: 50 kHz or 500 kHz
• Input Mode: Phase Differential, Increment/Decrement, or Pulse + Direc-
• Reset method: Phase Z and software reset, or Software reset
• Counter Operation: Circular Counter or Linear Counter
• Counter Data Display: Frequency measurement (mode 2)
• Turn ON the High-speed Counter 1 Start Bit (A860.00) and start the
• Specify the rotation direction in the Measurement Direction Bit (A860.03).
• Turn ON the Measurement Start Bit (A860.02).
• Monitor the high-speed counter’s frequency in A854 and A855.
and start the high-speed counter.
(high-speed counter 1) or A856 and A857 (high-speed counter 2).
Counter data display).
(high-speed counter 1) or A856 and A857 (high-speed counter 2).
Operation.
tion
high-speed counter.
OFF is forward, ON is reverse.
put, Counter data display).
Section 7-5