System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
A860
A861
A862
A863
A864
A865
Address
03
04
05
06
07
08
09
10 to 15
00
01
02
03
04
05
06
07
08
09
10 to 15
00 to 15
00 to 15
00 to 15
00 to 15
Bits
High-
speed
counter 1
com-
mand
bits
High-
speed
counter 2
com-
mand
bits
High-
speed
counter 1
monitor
data
High-
speed
counter 2
monitor
data
Measurement Direction Bit
(measurement mode 2)
Range Comparison Results
Clear Bit
Absolute Offset Preset Bit
Absolute Present Value Preset
Bit
Absolute Number of Rotations
Read Bit
Latch Input 1 Enable Bit
Latch Input 2 Enable Bit
Reserved
Start Bit
Reset Bit
Measurement Start Bit
Reserved
Range Comparison Results
Clear Bit
Absolute Offset Preset Bit
Absolute Present Value Preset
Bit
Absolute Number of Rotations
Read Bit
Latch Input 1 Enable Bit
Latch Input 2 Enable Bit
Reserved
Range Compari-
son Execution
Results Flags
Output Bit Pat-
tern
Range Compari-
son Results
Output Bit Pat-
tern
Name
OFF: Forward (up)
ON: Reverse (down)
This bit specifies the up/down direction of the pulse
input for frequency measurement.
Note Always set this bit before turning ON the Mea-
OFF: Does not clear the execution results (A862) or
output bit pattern (A863) from CTBL(882) execution
for range comparison for the counter.
ON: Clears the execution results (A862) or output bit
pattern (A863) from CTBL(882) execution for range
comparison for the counter.
OFF: Does not preset the offset.
OFF to ON: Stores the number of multi-turns read
from the Servo Driver and the number of initial incre-
mental pulses as an offset in the Absolute Offset
value in the System Setup.
When establishing the machine origin, the position
from the absolute encoder origin is set as the Abso-
lute Offset in the System Setup as the machine ori-
gin.
OFF: Disables the absolute present value preset.
OFF to ON: Stores the Absolute PV in the counter 1
PV (A850 and A851).
Note Refer to 7-7-6 Absolute Present Value for
OFF: Disables reading the number of rotations data
from the Servo Driver.
OFF to ON: Outputs the SEN output to the Servo
Driver and receives the number of rotations data on
the phase A input.
OFF: Disables the exterior latch input 1 signal.
ON: Enables the exterior latch input 1 signal.
OFF: Disables the exterior latch input 2 signal.
ON: Enables the exterior latch input 2 signal.
---
Same as command bits for high-speed counter 1.
Contains the CTBL(882) execution results for range
comparison. Bits 00 to 15 correspond to ranges 1 to
16.
OFF: No match
ON: Match
Contains the output bit pattern when a match is
found for CTBL(882) execution results for range com-
parison
Note If more than one match is found, an OR of the
Same as for high-speed counter 1 monitor data.
surement Start Bit.
details on the absolute PV.
output bit patterns with matches will be stored
here.
Function
Appendix C
User
User
Module
Controlled by