Operation Settings at Startup and Maintenance Functions
Auxiliary Area Flags
5-7-4
160
Comment Memory Function
Note
The backup status will be displayed in a Memory Backup Status Window by
the CX-Programmer when backing up data from the CX-Programmer for
transfer operations other than normal data transfers (PLC/Transfer). To
obtain this window, display of the backup status dialog box must be selected
in the PLC properties and Window/PLC Memory Backup Status must be
selected from the View Menu. For normal transfer operations (PLC/Transfer),
the backup status will be displayed in the transfer window after the transfer
status for the program and other data. Never turn OFF the FQM1 power dur-
ing these backup operations. The flash memory will be corrupted if the power
is turned OFF.
The internal flash memory in the FQM1 contains a comment memory area.
The following comment data and section data can be stored in or read from
the comment memory.
Flash Memory Error
Flag
• The automatic backup is executed whenever the Module user program or
• The user program and parameter data written to flash memory is auto-
• Variable table file (includes the CX-Programmer’s variable names and I/O
• Comment file (CX-Programmer’s rung comments and annotations)
parameter area is written (e.g., for data transfer operations from the CX-
Programmer and online editing).
matically transferred to user memory at startup.
comments)
Name
Automatic backup
User memory
Flash memory
Module
A403.10
Address
Automatically restored when Module is turned ON.
Turns ON when the flash memory is cor-
rupted.
User program
Parameters
Meaning
Data transfer from
CX-Programmer
Transfer operation
Online editing from
CX-Programmer
Section 5-7