XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 444

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
A858
A859
A860
Address
06
07
08
09 to 11
12
13 to 15
00
01
02
03
04
05
06
07
08
09 to 11
12
13 to 15
00
01
02
Bits
High-
speed
counter 1
status
High-
speed
counter 2
status
High-
speed
counter 1
com-
mand
bits
Measuring Flag (measurement
mode 1 or 2)
High-speed Counter Operating
Flag
Count Latched Flag
Reserved
Absolute Offset Preset Error
Flag
Reserved
Target Comparison In-progress
Flag
PV Overflow/Underflow Flag
Reserved
Phase Z Input Reset Flag (ON
for one cycle)
Absolute No. of Rotations Read
Error Flag
Absolute No. of Rotations Read
Completed Flag
Measuring Flag (measurement
mode 1 or 2)
High-speed Counter Operating
Flag
Count Latched Flag
Reserved
Absolute Offset Preset Error
Flag
Reserved
Start Bit
Reset Bit
Measurement Start Bit
Name
OFF: Changes in the counter PV or the counter fre-
quency is not being measured.
ON: Changes in the counter PV or the counter fre-
quency is being measured.
In measurement mode 1, this flag will turn ON at the
beginning of the sampling time after the Measure-
ment Start Bit (A860.02) is turned ON.
Note Valid when Counter Data Display in System
OFF: Counter is not operating.
ON: Counter is operating.
OFF: Count has not been latched.
ON: Latching the count has been completed for the
latch input.
---
OFF: No error occurred when saving the absolute
offset.
ON: An error occurred when saving the absolute off-
set.
---
Same as for high-speed counter 1.
OFF: Stops counter operation. The counter PV will
be maintained.
ON: Starts counter operation. The counter PV will
not be reset.
OFF: If a software reset is set in the System Setup,
the counter PV will not be reset when internal I/O is
refreshed in the Motion Control Module. If a phase Z
+ software reset is set, disables the phase Z input.
ON: If a software reset is set in the System Setup,
resets the counter PV to 0 when internal I/O is
refreshed in the Motion Control Module. If a phase Z
+ software reset is set, enables the phase Z input.
OFF: Disables measuring changes in counter PV or
the counter frequency.
ON: Starts measuring changes in counter PV or the
counter frequency.
Note Measuring the high-speed counter frequency
Note Valid when Counter Data Display in System
Setup is set to Counter Movements (mode 1)
or Frequency (mode 2).
is possible only for high-speed counter 1.
Setup is set to Counter Movements (mode 1)
or Frequency (mode 2).
Function
Appendix C
Module
Module
User
Controlled by
417