XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 465

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
438
Auxiliary Area Allocations
A858
A859
Word
00
01
03
04
05
06
07
08
12
00
01
03
04
05
06
07
08
12
Bits
High-
speed
counter 1
status
High-
speed
counter 2
status
Target Comparison In-progress
Flag
PV Overflow/Underflow Flag
Phase Z Input Reset Flag (ON for
one cycle)
Absolute No. of Rotations Read
Error Flag
Absolute No. of Rotations Read
Completed Flag
Measuring Flag (measurement
mode 1 or 2)
Note Valid when Counter Data
Display in System Setup is set to
Counter Movements (mode 1) or
Frequency (mode 2).
High-speed Counter Operating
Flag
Count Latched Flag
Absolute Offset Preset Error Flag
Target Comparison In-progress
Flag
PV Overflow/Underflow Flag
Phase Z Input Reset Flag (ON for
one cycle)
Absolute No. of Rotations Read
Error Flag
Absolute No. of Rotations Read
Completed Flag
Measuring Flag (measurement
mode 1 or 2)
High-speed Counter Operating
Flag
Count Latched Flag
Absolute Offset Preset Error Flag
Name
OFF: Target value comparison is not being performed for CTBL(882).
Note This flag is always OFF for range comparison.
ON: Target value comparison is being performed for CTBL(882).
Note Target comparison is continued without interruption once it has
been started (as opposed to range comparison), so this flag can be
used to check whether target comparison is in progress.
OFF: There is no counter overflow or underflow in Linear Counter
Mode. This flag will always be OFF in Circular Counter Mode.
ON: There is a counter overflow or underflow in Linear Counter
Mode. The counter PV will be fixed at the overflow or underflow limit.
This flag will be cleared when the High-speed Counter Start Bit is
turned OFF.
ON for one cycle when the counter PV is reset with the counter reset
method set to a phase Z + software reset.
Note This flag will turn ON for one cycle after the counter PV is reset
if the phase Z signal (reset input) turns ON while the High-speed
Counter Reset Bit (A860.01) is ON.
OFF: No error
ON: Error
OFF: Rotations being read or reading has not been executed.
ON: Reading has been completed (Turned ON when serial reception
of the number of rotations has been completed.)
OFF: Changes in the counter PV or the counter frequency is not
being measured.
ON: Changes in the counter PV or the counter frequency is being
measured.
In measurement mode 1, this flag will turn ON at the beginning of the
sampling time after the Measurement Start Bit (A860.02) is turned
ON.
OFF: Counter is not operating.
ON: Counter is operating.
OFF: Count has not been latched.
ON: Latching the count has been completed for the latch input.
OFF: No error occurred when saving the absolute offset.
ON: An error occurred when saving the absolute offset.
Same as for high-speed counter 1.
Function
Appendix D