Pulse Inputs
7-5-7
Pulse Inputs
Phases A and B
Phase Z
7-5-8
High-speed Counter Function Description
Input Signal Type and
Count Mode
208
Internal Circuit Configurations
Pulse Input Function Description
The pulse input function uses the high-speed counters. The pulse input func-
tion can be used to monitor changes (movement) in the high-speed counter
PV (mode 1) or changes in the high-speed counter frequency (mode 2).
High-speed counters 1 and 2 support the following inputs. The input method
application depends on the signal type.
Phase Differential Inputs
This method uses the phase Z signal and the two phase signals (phase A and
phase B) for a 1, 2, or 4 phase differential. The count is incremented or
decremented according to the offset between the two phase signals.
Increment/Decrement Pulse Inputs
The phase-A signal is the UP pulse and the phase-B signal is the DOWN
pulse. The count is incremented or decremented by these pulses.
Pulse + Direction Inputs
The phase-A signal is the pulse signal and the phase-B signal is the direction
signal. The count is incremented or decremented based on the ON/OFF sta-
tus of the phase-B signal.
+
+
1
2
1
2
4.4 k
3.0 k
1 24-V input
2 Line-driver input
1 24-V input
2 Line-driver input
Phase Z
internal circuit
Phase A and B
internal circuits
Section 7-5