XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 440

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
FQM1-MMA22 Motion Control Modules with Analog I/O
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
A877
A878
A879
A880
A881
A882
A883
A800
A802
A809
Address
Address
00
01
02 to 15
00 to 06
07
08 to 13
14
15
00 to 15
00 to 15
00 to 15
00 to 15
00 to 15
00 to 15 Analog Input PV
00
01 to 06
07
08
09
10 to 14
15
01 to 15 Number of Analog
Bits
Bits
Analog Input Sta-
tus
Samples
Pulse
Output 2
Com-
mand
Bits
Pulse
Output
Control
Bits
(Apply to
both
pulse
outputs 1
and 2.)
Reserved ---
Pulse
Output 1
Monitor
Data
Pulse
Output 2
Monitor
Data
Name
PV Reset Bit
Range Comparison Results
Clear Bit
Reserved
Reserved
Speed Change Cycle Bit
Reserved
PLS2 Pulse Output Direction
Priority Mode Bit
Reserved
Range Comparison Results
Output Bit Pattern
Range Comparison Results
Output Bit Pattern
Name
Contains the value input from the analog input port (using either the END
refresh or immediate refresh) in 4-digit hexadecimal.
The PV range depends on the input range:
• 0 to 10 V:
• 0 to 5 V or 1 to 5 V:
• 10 to 10 V:
User Adjustment Com-
pleted
Reserved
Analog Sampling Started OFF: Not started
Factory Adjustment Data
Error
User Adjustment Data
Error
Reserved
Analog Sampling Overlap OFF: Normal sampling
Indicates the number of data samples actually input since sampling started.
Same as for Pulse Output 1 Command Bits.
---
OFF: Sets the speed change cycle to 2 ms during
pulse output for ACC(888) or PLS2(887).
ON: Sets the speed change cycle to 1 ms during
pulse output for ACC(888) or PLS2(887).
---
OFF: Sets Direction Priority Mode.
In Direction Priority Mode, pulses are output only
when the pulse output direction and the direction of
the specified absolute position are the same.
ON: Sets Absolute Position Priority Mode.
In Absolute Position Priority Mode, pulses are always
output in the direction of the specified absolute posi-
tion.
---
---
Contains the CTBL(882) execution results for range
comparison. Bits 00 to 15 correspond to ranges 1 to
16.
OFF: No match
ON: Match
Contains the output bit pattern when a match is
found for CTBL(882) execution results for range com-
parison
Note If more than one match is found, an OR of the
Same as for Pulse Output 1 Monitor Data.
FE70 to 20D0 hex
FF38 to 1068 hex
DDA0 to 2260 hex
OFF: Not adjusted
ON: Adjustment completed
ON: Started
OFF: No Error
ON: Error (Checked at power ON.)
OFF: No Error
ON: Error (Checked at power ON.)
ON: The next sampling operation occurred before
the present sampling operation completed.
output bit patterns with matches will be stored
here.
Function
Function
Appendix C
User
---
Module
Controlled by
Module
Controlled
by
413