XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 470

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
Error Codes and Error Flags
Note
D-2
D-2-1
FQM1 memory addresses are set in Index Registers (IR0 or IR15) to indirectly address I/O memory. In gen-
eral, FQM1 memory addresses are set in Index Registers with Index Register setting instructions such as
MOVR(560) or MOVRW(561). Some instructions, such as FIND MAXIMUM (MAX(182)) and FIND MINIMUM
(MIN(183)), output the results of processing to an Index Register to indicate an FQM1 memory address. FQM1
memory addresses are set into the Index Registers automatically when calling subroutines with JSB(982).
There are also instructions for which Index Registers can be directly designated to use the FQM1 memory
addresses stored in them by other instructions. These instructions include DOUBLE MOVE (MOVL(498)),
some symbol comparison instructions (=L,<>L, <L, >L,<=L, and >=L), DOUBLE COMPARE (CMPL(060)),
DOUBLE INCREMENT BINARY (++L(591)), DOUBLE DECREMENT BINARY (– –L(593)), DOUBLE SIGNED
BINARY ADD WITHOUT CARRY (+L(401)), and DOUBLE SIGNED BINARY SUBTRACT WITHOUT CARRY
(–L(411)).
The FQM1 memory addresses all are continuous and the user must be aware of the order and boundaries of
the memory areas. As reference, the FQM1 memory addresses are provided in the next page.
Note Directly setting FQM1 memory addresses in the program should be avoided whenever possible. If FQM1
D-2-2
There are two classifications of the RAM memory (with capacitor backup) in the FQM1.
Parameter Areas: These areas contain Coordinator Module system setting data, such as the System Setup.
Auxiliary Area Allocations
System-defined
fatal errors
System-defined
non-fatal errors
User-defined
fatal errors
User-defined
non-fatal errors
Classification
memory addresses are set in the program, the program will be less compatible with new Modules for
which changes have been made to the layout of the memory.
(1) Codes C101 to C2FF will be stored for FALS numbers 001 to 511.
(2) Codes 4101 to 42FF will be stored for FAL numbers 001 to 511.
(3) Only the contents of A295 is stored as the error flag contents for program errors.
(4) 0000 hex will be stored as the error flag contents.
Memory Map (Actual FQM1 Memory Addresses)
FQM1 Memory Addresses
Memory Configuration
80F1
80C0 to 80C1
80CF
80CE
80CD
80E0
80F0
809F
80E9
80E1
009B
0200 to 020F
030A to 035F,
03FF
C101 to C2FF
4101 to 42FF
Error code
Sync bus error
Cycle time too long error
System Setup setting error
CPU Bus Unit error
FAL instruction executed (See note 2.)
Memory error
I/O bus error
Bus error (location undetermined)
No End Cover
I/O setting error
Program error
Duplicated number error
Too many I/O points error
Special I/O Unit error
FALS instruction executed (See note 1.)
Meaning
A403
A404
---
---
A295
---
A410 to A416
A407
A409
A417
A418 to A423
---
---
Error flags
Appendix D