Error Processing
Program
error
I/O Table
Setting
error
Dupli-
cated
Number
error
Too Many
I/O Points
error
Error
80F0
80E0
80E9
80E1
code (in
A400)
Error
A401.09: Pro-
gram Error Flag
A295: Program
error information
A401.10: I/O
Setting Error
Flag
A410: CPU Bus
Unit Duplicate
Number Flags
A411 to A416:
Special I/O Unit
Duplicate Num-
ber Flags
A401.11: Too
Many I/O Points
Flag
A407: Too Many
I/O Points,
Details
Auxiliary Area
flag and word
data
The program is incorrect. A bit in
A405 will turn ON to show the error
details as listed below.
A295.11: No END error
A295.15: UM overflow error
The last address in UM (user pro-
gram memory) has been exceeded.
A295.13: Differentiation overflow
error
Too many differentiated instructions
have been inserted or deleted dur-
ing online editing.
A295.12: Task error
A task error has occurred. The task
specified in the MSKS instruction
doesn’t exist.
A295.14: Illegal instruction error
The program contains an instruction
that cannot be executed.
More than 5 Motion Control Modules
are connected.
An unsupported CJ-series Unit has
been mounted.
The same unit number has been
allocated to more than one CPU Bus
Unit.
Note A410.00 to A410.15 corre-
The same unit number has been
allocated to more than one Special I/
O Unit.
Note A411.00 to A416.15 corre-
A Special I/O Unit has a unit number
setting between 0 and 9.
The probable causes are listed
below. The 3-bit binary value (000 to
101) in A407.13 to A407.15 indi-
cates the cause of the error. The
value of these 3 bits is also output to
A407.00 to A407.12.
1. The total number of I/O points al-
2. The number of Expansion Racks
3. More than 10 I/O Units are con-
located to Basic I/O Units exceeds
the maximum allowed (320 I/O
points). (bits: 000)
exceeds the maximum (bits: 101).
nected to one Rack (bits: 111).
spond to unit numbers 0 to F.
spond to unit numbers 0 to 95.
Probable cause
Check A405 to determine the type of
error that occurred.
Correct the program and then clear the
error.
Be sure that there is an END instruction
at the end of the program.
Use the CX-Programmer to transfer the
program again to FQM1.
After writing any changes to the program,
switch to PROGRAM mode and then
return to MONITOR mode to continue
editing the program.
Check that all of the task numbers speci-
fied in the MSKS instructions have corre-
sponding tasks.
Use MSKS to mask any input interrupt
task or other interrupt tasks that are not
being used and that do not have pro-
grams set for them.
Check and correct the program.
Check whether the number of Modules is
incorrect. If the number of Modules is
incorrect, turn OFF the power supply and
correctly connect the Modules.
Remove the unsupported CJ-series Unit
and turn the power ON again.
Check the CPU Bus Unit unit numbers,
eliminate the duplications, and turn the
Rack’s power supply OFF and then ON
again.
Check the Special I/O Unit unit numbers,
eliminate the duplications, and turn the
Rack's power supply OFF and then ON
again.
Set all Special I/O Unit unit numbers to
10 or higher.
Correct the problem and then turn the
power supply OFF and back ON.
Possible remedy