3-2
xx
Safety Precautions
Application Precautions
!WARNING
!Caution The operating environment of the FQM1 System can have a large effect on
!Caution Failure to abide by the following precautions could lead to faulty operation of
the longevity and reliability of the system. Improper operating environments
can lead to malfunction, failure, and other unforeseeable problems with the
FQM1 System. Make sure that the operating environment is within the speci-
fied conditions at installation and remains within the specified conditions dur-
ing the life of the system.
Always heed these precautions. Failure to abide by the following precautions
could lead to serious or possibly fatal injury.
the FQM1 or the system, or could damage the FQM1. Always heed these pre-
cautions.
• Locations subject to static electricity or other forms of noise
• Locations subject to strong electromagnetic fields
• Locations subject to possible exposure to radioactivity
• Locations close to power supplies
• Always connect to a ground of 100
• Always connect to a ground of 100
• Always turn OFF the power supply to the FQM1 before attempting any of
• Always use the CX-Programmer (Programming Device for Windows) to
• The user program, parameter area data, and part of the DM Area in the
• The FQM1 will start operating in RUN mode when the power is turned ON
• Configure the external circuits so that the control power supply turns ON
Not doing so may result in electric shock.
functional ground and line ground terminals of the Power Supply Unit, in
particular.
the following. Not turning OFF the power supply may result in malfunction
or electric shock.
create new cyclic tasks and interrupt tasks.
Coordinator Module and Motion Control Modules is backed up in the built-
in flash memory. Do not turn OFF the power supply to the FQM1 while the
user program or parameter area data is being transferred. The data will
not be backed up if the power is turned OFF.
with the default settings (i.e., if the operating mode at power ON (startup
mode) setting in the System Setup is disabled).
after the power supply to the FQM1 turns ON. If the power is turned ON in
the opposite order, the built-in outputs and other outputs may momen-
tarily malfunction and the control outputs may temporarily not operate cor-
rectly.
• Mounting or dismounting Power Supply Units, Coordinator Modules,
• Assembling the Modules
• Setting DIP switches
• Connecting or wiring the cables
• Connecting or disconnecting the connectors
Motion Control Modules, I/O Units, Special I/O Units, CPU Bus Units,
and End Modules
or less when installing the FQM1.
or less when short-circuiting the
3