Special I/O Unit Settings
Error-related Settings
I/O Errors
Memory Errors
420
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
A330 to
A335
A502 to
A507
A401
A407
A404
A403
Address
Address
Address
00 to 15 Special I/O Unit Initializ-
00 to 15 Special I/O Unit Restart
10
11
13
00 to 12 Too Many I/O Points,
13 to 15 Too Many I/O Points,
00 to 07 I/O Bus Error Slot Num-
08 to 15 I/O Bus Error Rack
05
08
Bits
Bits
Bits
ing Flags
Bits
I/O Setting Error Flag
Too Many I/O Points
Flag
Duplication Error Flag
Details
Cause
ber
Number
Registered I/O Table
Memory Error Flag
CPU Bus Unit Settings
Memory Error Flag
Name
Name
Name
These flags are ON while the corresponding Special I/O Unit is initial-
izing after its Special I/O Unit Restart Bit (A502.10 to A507.15) is
turned from OFF to ON or the power is turned ON.
Note Unit numbers 0 to 9 cannot be set on Special I/O Units, so
Turn these bits ON to restart (initialize) the Special I/O Unit with the
corresponding unit number. Bits A502.10 to A507.15 correspond to
unit numbers 10 to 95.
ON when more than 5 Motion Control Modules are connected to the
Coordinator Module.
ON when a Unit model registered in the I/O table does not match the
model actually connected.
ON in the following cases:
• Two CPU Bus Units have been assigned the same unit number.
• Two Special I/O Units have been assigned the same unit number or a
• Two Basic I/O Units have been allocated the same data area words.
The cause of the Too Many I/O Points Error is indicated in binary in
A407.13 to A407.15. The 13-bit binary value in A407.00 to A407.12
indicates the details: the excessive value or the duplicated unit num-
ber.
• The number of I/O points will be written here when the total number
• The number of interrupt inputs will be written here when the number
• The number of Racks will be written here when the number of Expan-
The 3-digit binary value of these bits indicates the cause of the Too
Many I/O Points Error and shows the meaning of the value written to
bits A407.00 to A407.12.
Contains the 2-digit slot number (00 to 09) where an I/O Bus Error
occurred. When the End Cover is not connected, 0E hex will be stored.
If the error location is undetermined, 0F hex will be stored.
Contains the 2-digit rack number (00 or 01) where an I/O Bus Error
occurred. When the End Cover is not connected, 0E hex will be stored.
If the error location is undetermined, 0F hex will be stored.
When a memory error occurs, the Memory Error Flag (A401.15) is
turned ON. This flag will be ON if the error occurred in the registered I/
O table.
When a memory error occurs, the Memory Error Flag (A401.15) is
turned ON. This flag will be ON if the error occurred in the CPU Bus
Unit Settings.
Special I/O Unit has been assigned a unit number between 0 and 9.
of I/O points set in the I/O Table (excluding Slave Racks) exceed the
maximum allowed for the Coordinator Module.
of interrupt inputs exceeds 32.
sion Racks exceeds the maximum.
A330.00 to A330.09 are not used.
Function
Function
Function
Appendix C
Module
User
Module
Module
Controlled by
Controlled by
Controlled by