XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 458

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
Auxiliary Area Allocations
A345
A392
A393
A394
A400
A401
Word
00
01
02
03
04
04
05
06
07
12
00 to 15 RS-232C Port Reception Counter (no-proto-
00 to 07 RS-232C Port PT Communications Flags
08 to 15 RS-232C Port PT Priority Registered Flags
00 to 07 Peripheral Port PT Communications Flags
08 to 15 Peripheral Port PT Priority Registered Flags
00 to 15 Error code
06
08
09
10
11
13
14
15
Bits
FB Program Information Flag
Symbol Table File Flag
Comment File Flag
Program Index File Flag
DM Data in FROM Flag
RS-232C Port Communications Error Flag
RS-232C Port Send Ready Flag (no-protocol
mode)
RS-232C Port Reception Completed Flag (no-
protocol mode)
RS-232C Port Reception Overflow Flag (no-
protocol mode)
RS-232C Port Settings Changing Flag
col mode)
FALS Error Flag
(fatal error)
Cycle Time Too Long Flag (fatal error)
Program Error Flag
(fatal error)
I/O Setting Error Flag
Too Many I/O Points Flag
Duplication Error Flag
I/O Bus Error Flag
Memory Error Flag (fatal error)
Name
ON when there is FB program data in the FB program memory.
Turns ON when the comment memory contains a symbol table file
(variable table file).
Turns ON when the comment memory contains a comment file.
Turns ON when the comment memory contains a program index file.
Turns ON when there is DM data saved in flash memory.
Turns ON when a communications error has occurred at the RS-
232C port.
Turns ON when the RS-232C port is ready to send data in no-proto-
col mode.
Turns ON when the RS-232C port has completed the reception in
no-protocol mode.
Turns ON when a data overflow occurred during reception through
the RS-232C port in no-protocol mode.
Turns ON while the RS-232C port’s communications settings are
being changed.
Indicates (in binary) the number of bytes of data received when the
RS-232C port is in no-protocol mode.
The corresponding bit will be ON when the RS-232C port is commu-
nicating with a PT in NT link mode or Serial PLC Link mode. Bits 0 to
7 correspond to units 0 to 7.
The corresponding bit will be ON for the PT that has priority when the
RS-232C port is communicating in NT link mode. Bits 0 to 7 corre-
spond to units 0 to 7.
The corresponding bit will be ON when the peripheral port is commu-
nicating with a PT in NT link mode. Bits 0 to 7 correspond to units 0
to 7.
The corresponding bit will be ON for the PT that has priority when the
peripheral port is communicating in NT link mode. Bits 0 to 7 corre-
spond to units 0 to 7.
When a non-fatal error (user-defined FAL(006) or system error) or a
fatal error (user-defined FALS(007) or system error) occurs, the
hexadecimal error code is written to this word.
Turns ON when a non-fatal error is generated by the FALS(006)
instruction. The FQM1 will stop operating.
Turns ON if the cycle time exceeds the maximum cycle time set in
the System Setup (the Watch Cycle Time).
ON when program contents are incorrect.
Module operation will stop.
Turns ON when more than four Motion Control Modules are con-
nected to the Coordinator Module.
ON when a Unit model registered in the I/O table does not match the
model actually connected.
ON in the following cases:
• Two CPU Bus Units have been assigned the same unit number.
• Two Special I/O Units have been assigned the same unit number or
• Two Basic I/O Units have been allocated the same data area words.
Turns ON when an error occurs in transferring data between the
Coordinator Module and Motion Control Modules. Module operation
will stop.
Turns ON when there is an error in the memory. FQM1 operation will
stop and the ERR indicators on the front of the Modules will light.
a Special I/O Unit has been assigned a unit number between 0 and
9.
Function
Appendix D
431