Intended Audience
Intended Audience
General Precautions
Safety Precautions
!WARNING
!WARNING
!WARNING
!WARNING
!WARNING
This manual is intended for the following personnel, who must also have
knowledge of electrical systems (an electrical engineer or the equivalent).
The user must operate the product according to the performance specifica-
tions described in the operation manuals.
Before using the product under conditions which are not described in the
manual or applying the product to nuclear control systems, railroad systems,
aviation systems, vehicles, combustion systems, medical equipment, amuse-
ment machines, safety equipment, petrochemical plants, and other systems,
machines, and equipment that may have a serious influence on lives and
property if used improperly, consult your OMRON representative.
Make sure that the ratings and performance characteristics of the product are
sufficient for the systems, machines, and equipment, and be sure to provide
the systems, machines, and equipment with double safety mechanisms.
It is extremely important that the FQM1 be used for the specified purpose and
under the specified conditions, especially in applications that can directly or
indirectly affect human life. You must consult with your OMRON representa-
tive before applying an FQM1 System to the above-mentioned applications.
Do not attempt to take any Modules apart while the power is being supplied.
Doing so may result in electric shock.
Do not touch any of the terminals or terminal blocks while the power is being
supplied. Doing so may result in electric shock.
Do not attempt to disassemble, repair, or modify any Modules. Any attempt to
do so may result in malfunction, fire, or electric shock.
Provide safety measures in external circuits, i.e., not in the Flexible Motion
Controller (referred to as the “FQM1”), to ensure safety in the system if an
abnormality occurs due to malfunction of the FQM1 or another external factor
affecting the FQM1 operation. Not doing so may result in serious accidents.
• Personnel in charge of installing FA systems.
• Personnel in charge of designing FA systems.
• Personnel in charge of managing FA systems and facilities.
• Emergency stop circuits, interlock circuits, limit circuits, and similar safety
• The FQM1 will turn OFF all outputs when its self-diagnosis function
• The FQM1 outputs may remain ON or OFF due to destruction of the out-
measures must be provided in external control circuits.
detects any error or when a severe failure alarm (FALS) instruction is exe-
cuted. As a countermeasure for such errors, external safety measures
must be provided to ensure safety in the system.
put transistors. As a countermeasure for such problems, external safety
measures must be provided to ensure safety in the system.
1