Built-in I/O Area: CIO 2960 and CIO 2961
These words are allocated to built-in I/O terminals the Coordinator Module or Motion Control Module.
Cyclic Refresh Bit Area: CIO 4000 to CIO 4039 for Coordinator Module (CIO 4000 to
CIO 4009 for Motion Control Modules)
In the Coordinator Module, 10 words are refreshed every cycle for each Motion Control Module. These words
contain Motion Control Module status, general-purpose I/O, and other information. (Refreshing these words is
not necessarily synchronized with the Motion Control Module Cycles.)
This area can be used to transfer information between Modules that does not required high-speed exchange.
The user can allocate the information to be transferred and the information can be used accessed from the lad-
der programs in the Coordinator Module and Motion Control Modules to coordinate programming.
Synchronous Data Link Bit Area: CIO 1200 to 1219
Each Module (Coordinator Module and Motion Control Modules) broadcasts up to two items (four words) of
data at the specified cycle. The data can be specified separately for each Module and is allocated for this area.
All of the linked Modules can access the data that is broadcast by other Modules.
Work Areas
These words can be used only in the program; they cannot be used for I/O exchange with external I/O termi-
nals. Be sure to use the work words provided in the Work Area before allocating the work words in the CIO
Areas.
Serial PLC Link Bit Area: CIO 3100 to CIO 3189
These words are used for data links with OMRON PLCs.
Addresses not used for Serial PLC Link can be used only in the program, the same as the Work Area.
I/O Area: CIO 0000 to CIO 0019
These words are allocated to external I/O terminals on CJ-series Basic I/O Units. Words that aren't allocated
may be used only in the program as work words.
CPU Bus Unit Area: CIO 1500 to CIO 1899
These words are allocated to CJ-series CPU Bus Units to transfer status information. Each Unit is allocated 25
words and up to 16 Units (with unit numbers 0 to 15) can be used. Words that aren’t used by CPU Bus Units
may be used only in the program as work words.
Special I/O Unit Area: CIO 2100 to CIO 2959
These words are allocated to CJ-series Special I/O Units. Each Unit is allocated 10 words and up to 86 Units
(unit numbers 10 to 95) can be used). Words that aren’t used by Special I/O Units may be used only in the pro-
gram as work words.
368
I/O Memory
• Serial PLC Link Bit Areas (Coordinator Module)
• I/O Area (Coordinator Module)
• CPU Bus Area (Coordinator Module)
• Special I/O Unit Area (Coordinator Module)
• DeviceNet Area (Coordinator Module)
• FB Instance Area
• CIO 3100 to (CIO 3100 + No. of linked words
• (CIO 3100 + No. of linked words) to (CIO 3100 + No. of linked words + No. of linked words
Coordinator Module to CJ1M
1): CJ1M to FQM1 Coordinator Module
Appendix B
1): FQM1