XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 61

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
Function Tables Arranged by Purpose
1-7-4
34
Detecting speed
using rotary
encoder inputs
Measuring
undulation, dis-
tortion, thick-
ness, height, or
diameter, etc., of
an object
High-speed Analog I/O Control
Purpose
Purpose
Detecting speed
and use in out-
put control while
managing posi-
tion using
encoder inputs
Monitoring
speed while
managing work-
piece position
using encoder
input
High-speed
tracing of analog
data when
external signal
turns ON
High-speed
tracing of analog
data synchro-
nized with tar-
get object
position
Measuring dis-
placement of
workpiece per
unit time
Measure input
pulse cycle
Storing analog
input value in
memory at
specified time
(constant cycle)
Storing analog
inputs to DM
Area synchro-
nous with posi-
tion (pulse input)
Operation
Operation
Monitoring High-
speed Counter
Movement
(cycle time)
Monitoring High-
speed Counter
Movement
(sampling time
specified)
Counter fre-
quency mea-
surement (pulse
input 1 only)
• Interval timer
• PRV(881)
High-speed
analog sam-
pling function
Main functions
Main functions
interrupts
instruction
used
used
7-5-8 Pulse Input Function Description
Outputs the change in the high-speed counter
PV each cycle, while outputting number of input
pulses as high-speed counter PV.
Used for applications such as detecting speed of
external master axis during synchronous con-
trol.
7-5-8 Pulse Input Function Description
Outputs the change in the high-speed counter
PV each sampling cycle (1 to 9,999 ms) speci-
fied asynchronously to Motion Control Module
cycle.
Used for applications such as detecting external
device speed or number of pulses within a spec-
ified time (not used for output control).
7-5-8 Pulse Input Function Description
Number of input pulses can be monitored simul-
taneously as high-speed counter PV and pulse
frequency.
7-9-3 Analog Input Function Specifications
Can perform analog sampling at a constant
cycle, using scheduled interrupt processing in
analog input immediate refresh mode.
Sampling can be executed at small time inter-
vals using analog input conversion (40 s).
Data stored in memory can also be displayed on
PT and other display devices, e.g., to show
trends.
7-9-7 High-speed Analog Sampling (FQM1-
MMA22 Only)
Sampling of target measurement object position
as compared to the sampling based on time.
Interrupt tasks, as outlined above, are not used,
so even more detailed sampling is possible.
Used for applications such as generating dis-
placement data for the measurement object
from one position to another position.
Details
Details
Section 1-7